TRUST 1000 UPS ENERGY PROTECTOR
9. Ask your local authority where to dispose the replaced batteries at an
appropriate recycling facility.
UK
5.5 Technical specifications 5.5 Technical specifications
Model 1000 Model 1000
Output capacity 1000 VA/600 W
115 VAC/230 VAC
Voltage range 170 ~ 274 VAC
Input
Frequency 47-63 Hz
115 VAC/230 VAC
Frequency 50 o 60 Hz
Output
Freq. regulation +/- 1 Hz
Surge current protection [J] Max. 150
Max. surge current [Amp] 6,500 A
Transfer time (typical) Less than 3 ms
Battery type &
number
12 V/7 AH x2 battery
Backup time
(min.)
38 ~ 70
Battery
Charge time 8 hours to 90% after full discharge
Working
surroundings
0 – 40
° C, 0-90% relative humidity
Surroundings
Sound level Less than 40 dB
Weight 13.8 kg
6 Troubleshooting
Method
1. Read the solutions given below.
2. Check for up-to-date FAQs, drivers and instruction
manuals on the Internet (
www.trust.com/13988
).
Problem Possible cause Solution
The UPS has not been
turned on.
Turn the UPS on by pressing the
ON/OFF button on the UPS for at
least 3 seconds.
The battery voltage is too
low.
Recharge the UPS.
The computer
cannot be turned
on.
The mains cable has not
been connected correctly
or is loose.
Connect the power cable correctly.
5