1
2
Installation
Installingthesolenoidvalveunit‒(ActuatorType)
Actuator
Turbocompressorpressuresource
(1)Installa6Φhosefittingtoboththe[1]&[2]portsonthesolenoidvalveunit.
(2)Assemblethevalveunitasshowninthepicture.
(3)DisconnectthefactoryhosebetweenActuatorandturbocompressor,and
connecttheTurbocompressortothe[1]portofthesolenoidvalveunit.
(4)Next,installtheprovided6ΦhosefromtheActuatortothe[2]portofthe
solenoidvalveunit.Adjustthelengthofthehoseasneeded.
*Refertopage14forvehiclesequippedwithafactoryboostpressuresolenoid
valve.
Important
・Don'tinstalltheproductinanyplacewhereitwillbesubjectedtodirectsunlightorhigh
temperatures.
・Makesuretousecabletiesonthehosesforsecureconnections.
・Wheninstallinghoses,becarefulnottokinkortwistthehoses.
・Audibleclickingnoisesfromvalveunitmaybeheardfromthesolenoid.Itisnormalandisnot
aproblem.
・Mountthevalveunitwiththeprovidedanti-vibrationisolators.