STARTTYPE
DetermineshowtheboostcontrollerwillfunctionuntiltheSTARTBOOSTvalue.
■Programming■
STARTTYPE
SET
SETUP
Boost
Time
0.7×100kPa
NORMAL
(limitedcontrol)
CONTROL
(Maximumcontrol)
(1)InthemainSETUPscreen,rotatetheSETDIALto
highlightST.TYPE.ThenpresstheSETDIALtoconfirm.
(2)RotatetheSETDIALtohighlightandselectCONTROLor
NORMAL.PresstheSETDIALtoconfirm.
*Tocancelandreturntotheprevioussettingandthe
mainSETUPscreen,pressMODE.
Configurations
CONTROL:START(BOOST)attemptstocontrolthewastegatewiththesolenoidvalve
fortheentireboostrange.
NORMAL:START(BOOST)onlyactivatestheboostcontrolsolenoidfromthe
programmedSTART(BOOST)valueon.
Example:
IftheSTARTBOOSTvalueisprogrammedat0.7x100kPa,CONTROLwillallowfor
quickerboostresponse.