PORTACOUNT
®
RESPIRATOR FIT TESTER
MODELS 8040 AND 8048
OPERATION/USER MANUAL
P/N 6010633, REVISION E
AUGUST 2019

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the TSI Instruments PORTACOUNT 8040 and is the answer not in the manual?

TSI Instruments PORTACOUNT 8040 Specifications

General IconGeneral
BrandTSI Instruments
ModelPORTACOUNT 8040
CategoryTest Equipment
LanguageEnglish

Summary

CHAPTER 1 Introduction and Overview

Why Fit Test

Explains the two primary reasons for respirator fit testing: verification of training and sizing.

Preparations for Fit Testing

Details the importance of training the trainer and respirator training.

Identifying Parts

Lists and describes the components included with the PortaCount Fit Testers.

CHAPTER 2 Prepare the PortaCount Fit Tester for Operation

Install the Twin Tube Assembly

Provides instructions on connecting the twin tube assembly to the PortaCount Fit Tester's inlet fittings.

Prepare the Alcohol Cartridge

Details the procedure for saturating the wick with isopropyl alcohol for accurate measurements.

Connect the PortaCount Fit Tester

Explains how to connect the PortaCount Fit Tester to a tablet or computer using a USB cable.

Supply Power to the PortaCount Fit Tester

Details how to connect the instrument to an AC power source and power it on/off.

Connect to FitPro Ultra Fit Test Software

Guides on launching and connecting to the FitPro Ultra Fit Test Software.

Connect Wirelessly (optional)

Describes how to configure the PortaCount Fit Tester for wireless communication via a Wi-Fi USB-A dongle.

CHAPTER 3 FitPro Ultra Fit Test Software Operation

The Main Menu

Introduces the main menu of the FitPro Ultra software and its options.

PortaCounts

Describes how to work with your PortaCount Fit Tester via the software.

People

Enables viewing, adding, editing, or deleting fit test subjects from the program.

Respirators

Allows viewing, adding, editing, or deleting respirator information.

Reporting

Provides access to basic report types like people, respirator, and fit test reports.

Fit Test History Feature and Multi-Respirator Fit Test Card Feature

Introduces features for viewing fit test records and printing multiple respirators on one card.

CHAPTER 4 Daily Checks

Particle Check

Checks if the instrument is working and ambient particle concentration is sufficient.

Classifier Check

Verifies the N95-Companion Technology Classifier functionality.

Zero Check

Ensures there are no leaks in the system by attaching a HEPA filter.

Maximum Fit Factor Check

Determines the instrument's ability to measure high fit factors.

Daily Check History Feature

Provides a quick method for viewing and searching daily check records.

CHAPTER 5 Real-Time FitCheck Mode

Real-Time Training

Allows subjects to experiment with adjustments and observe fit effects in real time.

Concentration Check

Measures particle concentration in the fit testing area for preparation.

CHAPTER 6 Fit Testing

Precautions for Fit Testing

Discusses precautions like avoiding smoking, generated aerosols, and irritant smoke.

About Respirators and Fit Testing

Covers fit testing methods and types of respirators.

Probed Test Respirators

Explains the use of respirators modified with sampling ports for fit testing.

Probes for Filtering-Facepiece (Disposable) Respirators

Details testing disposable respirators by inserting a test probe.

Inserting a Test Probe in a Disposable Respirator

Guides on installing a sampling port onto a disposable filtering-facepiece respirator.

Conducting a Fit Test

Provides step-by-step instructions for performing a quantitative fit test.

CHAPTER 8 Preventive Maintenance, Service, and Troubleshooting

Maintenance

Recommends annual cleaning and recalibration and provides service contact information.

Status Messages

Explains various status messages like 'Low Particle' and 'High Concentration'.

Shipping & Storage Precautions

Provides guidance on safely transporting and storing the PortaCount Fit Tester.

Changing the Alcohol Wick

Details when and how to change the alcohol wick in the cartridge.

Operation in High Humidity

Discusses challenges and recommendations for operating in high humidity environments.

Nozzle Cleaning

Provides procedures for clearing a clogged internal nozzle.

Troubleshooting

Lists common symptoms, causes, and solutions for PortaCount Fit Tester problems.