EasyManua.ls Logo

Tunstall Vi+ - Quick Codes

Tunstall Vi+
9 pages
Print Icon
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Programming the Vi+ using a Series Telephone
Page 9 Ver 1 4/24/2015
Quick Codes
The Tunstall Vi+ has a number of quick codes that can be entered into the series
telephone when the Vi+ is in programming mode
Quick
Code
Purpose
Comments
2040
Reset to default but retain radio triggers
Time and date remain unchanged
2050
Reset to factory defaults
Time and date remain unchanged
2051
Reset unit
Force unit to reset. All current
settings are retained.
2060
Delete ALL radio triggers
Restores to default
3000
Delete the next radio trigger transmitted
Must activate trigger
31xx
Enables periodic calls (30 day) with
offset of xx hours
3100
Disables periodic calls
32xx
Configure pendant test reminder function
Where XX is the number of days
betweenthe reminders, When XX is
set to 00 = the function is turned off
3300
Demonstrates the pendant test
reminder function
Unit plays spoken messages
48xy
Set destination
Where x is telephone number 1 to
10 ( 0 =10 ) y = 0 for CC, 1 for PR
and 2 for POTS
51xx
Enable inactivity monitoring for a period
of 12 or 24 hours
Where xx is 12 or 24
9101
Make all event calls silent and visual
Alarm button will flash
9108
Make all event calls silent and non-visual
Alarm button does not flash
9103
Restore all event calls to default states
3020
Announce date and time

Related product manuals