SIMRET 4000 INSTRUCTIONS
GETTING STARTED
The Simret 4000 is operated by a single Click control. The central OK button may be single-clicked,
double-clicked, or held-down. The surrounding arrow buttons are used to navigate menus by
moving a highlight bar through a menu of options on the instrument’s display screen. Clicking the
OK will select the highlighted item. Normally this will be accompanied by a beep from the
instrument. The scroll bar on the right hand side indicates the relative position of the item within the
menu.
Whenever possible the instrument operates to these simple rules:
single-click to choose a menu item
single-click to return
double-click to enter a 2
nd
level menu
single-click to return
hold-down (for more than one second) to abandon a course of action
Use or to increase or decrease a value.
Use the arrow buttons to scroll through a menu
the last option of a menu will return you to the previous menu, or use the button.
SWITCHING ON: To power the instrument, hold-down OK and then release. The display will
appear when OK is released. The instrument will perform a short self-test and display its
software version and when calibration is next due. The Start Menu will then appear.
The self-test will warn if re-calibration is overdue and if more than 80 tests have been stored
in memory. Upload or print the tests if the memory is getting full, then erase to create more
space. If the SD card is fitted, tests will be backed-up automatically to create space.
SWITCHING OFF: To manually switch off, hold-down OK in the Main Menu. If the control has
not been operated for about 4 minutes, the instrument will switch itself off unless it has been
armed for a test. It will also turn off if its battery is very low.
EDITING: A built-in editor allows certain number values, names and software switches to be edited
in the instrument. First highlight the item then for:
Simret 4000 Instructions, Issue 10, Jan 2011
© 1994-2011, Turnkey Instruments Ltd. Page 1 of 17

Other manuals for Turnkey Simret 4000

Question and Answer IconNeed help?

Do you have a question about the Turnkey Simret 4000 and is the answer not in the manual?

Summary

Getting Started with Simret 4000

Operation Basics

Explains how to navigate menus and interact with the Simret 4000 using its single Click control.

Power Management

Details the procedures for switching the instrument ON and OFF, including self-test sequences.

Editing Data Values

Describes how to edit numbers, names, and software switches using the instrument's editor.

Bluetooth Connectivity

Covers pairing the instrument with Bluetooth devices like printers and pedal pads.

Instrument Operation and Maintenance

Storage and Charging

Instructions for storing the instrument in its case and connecting the battery charger.

Wired Operation Mode

Explains how to connect peripherals using physical DIN connectors instead of Bluetooth.

Recalibration and Warranty

Information on annual recalibration requirements and extended warranty options.

Flat Battery Handling

Procedures to follow if the instrument's battery becomes completely discharged.

Brake Testing Procedures

Brake Effort vs Deceleration

Explains the difference between brake effort and deceleration measurements for vehicles.

Instrument Setup for Testing

Covers correct instrument positioning, using the Pedal Pad, and trigger options for tests.

Gradient Measurement

Details how to measure ground slope for accurate test results, especially for brake effort.

Test Execution and Arming

Step-by-step guide on arming the instrument and initiating a brake test.

Handling Test Results

Describes how to accept or reject test results, understand pass/fail lights, and view warnings.

Reviewing Stored Results

Instructions on accessing, printing, and erasing previously performed tests.

Data Management and Connectivity

SD Card Backup and Loading

Procedures for backing up and loading instrument data using an SD memory card.

Bluetooth Pedal Force Transducer

Details on using the Bluetooth Pedal Force Transducer for measurements.

Instrument Configuration Menus

Setup Instrument Menu Overview

Introduces the main menu for configuring instrument settings and parameters.

Adjust Values Menu

Explains how to modify specific test parameters and thresholds.

Setup Bluetooth Menu

Guides on searching, pairing, and managing Bluetooth devices.

Change Settings Menu

Describes how to adjust various system-wide settings like units, sampling rate, and beeper.

Turnkey ID Exporter Program

Software Overview and Connection

Information on the Turnkey ID Exporter program and connecting the instrument.

Data Export and Import

Steps for exporting and importing plant details, examiner names, and other data.

Turnkey Simret 4000 Specifications

General IconGeneral
BrandTurnkey
ModelSimret 4000
CategoryTest Equipment
LanguageEnglish