Digital Liquid Meter
Series 900 – High Flow
Models
900DB, 900DB1.5, 900DBBSPT, 900DB1.5BSPT
Owners Installation, Operation, and Safety Manual
mdi - Manufacturers Distributor Inc. | Phone: (813) 241 - 4900 | Fax: (813) 571 - 0422 | www.FillRitePumpSales.com | Sales@FillRitePumpSales.com

Questions and Answers

  • B
    Brendan HansonAug 13, 2025
    Why is my Tuthill Measuring Instruments counter inaccurate?
    • J
      Jonathan Blackburn MDAug 14, 2025
      An inaccurate counter in your Tuthill Measuring Instruments may be due to several reasons: * The meter might be mis-calibrated; in that case, check the calibration and recalibrate if needed. * There could be air in the lines or metering chamber; inspect line seals and joints for leaks and seal them. * The measuring gears or disc might be sticking; clean or replace the internal metering components.
  • M
    mhallAug 17, 2025
    What to do if my Tuthill Fill-Rite 900 have low flow capacity?
    • T
      Timothy GibsonAug 18, 2025
      If your Tuthill Measuring Instruments exhibit low flow capacity, it might be because the meter chamber is clogged. Try cleaning the meter chamber and also clean or replace any screens and filters in the piping.
  • S
    Sandra SmithAug 21, 2025
    What to do if my Tuthill Fill-Rite 900 nutating disc is broken?
    • T
      timothy32Aug 21, 2025
      If the nutating disc in your Tuthill Measuring Instruments is broken, this may be due to sudden high-pressure fluid hitting the disc. To prevent this, avoid surge flows by installing a shut-off valve on the outlet of the meter. Install the meter as close to the pump as possible, keeping the piping full of liquid. Replace the broken disc.
  • C
    Caitlin RhodesAug 25, 2025
    How to fix Tuthill Measuring Instruments meter body cracks?
    • J
      John ThomasAug 25, 2025
      Cracks in the meter body of your Tuthill Measuring Instruments can be caused by excess line pressure. Install a pressure relief valve to allow high pressure to bleed back to the tank. You may also need to replace the meter.
  • E
    erik89Aug 28, 2025
    How to prevent nutating disc broken in Tuthill Fill-Rite 900 Measuring Instruments?
    • C
      charles44Aug 28, 2025
      To prevent a broken nutating disc in Tuthill Measuring Instruments due to sudden high-pressure fluid, install a shut-off valve on the meter's outlet to avoid surge flows. Position the meter as close to the pump as possible and ensure the piping remains full of liquid. If damage has already occurred, replace the meter chamber assembly.
  • E
    emily74Sep 1, 2025
    What to do if meter body cracks in Tuthill Fill-Rite 900 Measuring Instruments?
    • L
      Lindsey WalkerSep 1, 2025
      If you observe cracks in the meter body of your Tuthill Measuring Instruments, it's likely due to excess line pressure. To resolve this, install a pressure relief valve to bleed high pressure back to the tank. Additionally, replace the meter.
  • B
    btaylorSep 4, 2025
    Why is there low flow capacity in Tuthill Measuring Instruments?
    • K
      kelly78Sep 5, 2025
      If your Tuthill Measuring Instruments exhibit low flow capacity, it could be due to a clogged meter chamber. Clean the meter chamber thoroughly. Additionally, clean or replace any screens and filters in the piping to ensure optimal flow.
  • G
    gstephensSep 9, 2025
    How to fix inaccurate counter in Tuthill Measuring Instruments?
    • B
      bakerleahSep 9, 2025
      If the counter on your Tuthill Measuring Instruments is inaccurate, there are several potential causes: * The meter may be mis-calibrated: Check the calibration and recalibrate as necessary. * There may be air in the lines or metering chamber: Inspect line seals and joints for leaks, and seal them appropriately. * The measuring disc could be sticking: Clean or replace the internal metering components as needed.

Summary

Safety Information

General Safety Precautions

Critical safety precautions for proper operation and to prevent injury or death.

Installation

Meter Installation Steps

Instructions for plumbing, rotating display, and sealing connections for meter installation.

Meter Calibration

Calibration Procedure and Notes

Steps for unit selection, dispensing, entering volume, and important operational notes.

Calibration Input and Error Handling

Detailed steps for inputting dispensed fluid volume and handling errors during calibration.

Operating Instructions

Meter Display and Button Functions

How to turn on the display, wake from sleep mode, and the function of the three buttons.

Low Battery Warning

Storage

Troubleshooting

Troubleshooting Guide

Basic digital diagnostics and repair guidance for common meter issues.

Fluid Compatibility

Fluid Compatibility Chart

Lists fluids compatible and not compatible with the 900DB series meter.

Assembly and Disassembly

Accessing the Battery

Instructions for accessing and replacing the meter's AA batteries.

Repair and Service

Meter Chamber Repair

Guidelines for repairing or replacing meter chamber components.

Safety Testing Approvals

Information on compliance with UL, cUL, ATEX, and other testing organizations.

Replacement Parts Information

900 Series Digital Meter Replacement Parts Kit

Details and part numbers for the meter replacement kit.

Electrical Installation Information

Internal Power (Battery Power)

Details on battery power supply, expected life, and low battery warning.

Tuthill Product Warranty

Information on the two-year limited warranty for heavy duty products.

Technical Specifications and Information

Meter Specifications

Key specifications including dimensions, accuracy, flow rate, and operating temperature.

Tuthill Fill-Rite 900 Series Specifications

General IconGeneral
BrandTuthill
ModelFill-Rite 900 Series
CategoryMeasuring Instruments
LanguageEnglish