Technical setting Steps
HeatingSwing
(SYSTEMHEAT)
Theswingsetting,often
calledcyclerate”,
“differentialor“anticipation”
isadjustable.Asmaller
swingsettingwill
causemorefrequentcucles
andalargerswingsetting
willcausefewercycles
Theheatingswing
settingisadjustablefrom
0.2˚to2˚.Forexample:A
swingsettingof0.5˚will
turntheheatingon
atapproimately0.5˚below
thesetpointandturnthe
heatingoffat
approximately0.above
thesetpoint.
FforFahrenheitCfor
Celsius
SelectforFahrenheit
temperaturereadoutselect
CforCelsiusreadout.
Thecompressorshortcycle
delayprotectsthe
compressorfrom
shortcycling.Thisfeature
willnotallowthe
compressortobeturnedon
for5minutesafteritwas
lastturnedo.
Compressor
ShortCycle
Delay
SelectingONwillnotallow
thecompressortobe
turnedonfor5minutes
afterthelasttimethe
compressorwasswitched
off.SelectOFFtoremove
thiselay.
21
SelectGASforsystemsthat
controlthefanduringacall
forheat.
SelectELECtohave
thethermostatcontrolthe
fanduringacallforheat.
FanOperation
Usethe+or‒keyto
selectGASorELEC

Related product manuals