ERRORS
*All errors are logged in memory.
*Only door error is displayed on the display and has an
audible signal.
*For 68118 models, pump error is displayed via alert light
with no audible alert.
E1: Thermistor 1 open.
E2: Thermistor 2 open.
E3: Thermistor 3 open.
E4: Thermistor 4 open.
E5: Thermistor 1 shorted.
E6: Thermistor 2 shorted.
E7: Thermistor 3 shorted.
E8: Thermistor 4 shorted.
E9: Door open error.
PI: Pump Circuit open
Programming the unit to correct model number
1. Unplug unit and install new board
2. Push and hold the hidden icon
3. Plug the unit in
4. Release the hidden icon
5. Use the UP/DOWN arrows to scroll to correct model
number from chart
6. Push and release the light icon
7. Unit flashes OFF/ON then locks in model
1000 Model
#
2000
(120V)
Model
#
2000
(230V)
Model
#
1215R 07 2218R 05 2245R 55
1215WC 12 2218RG 04 2245RDC 54
1224BEV 13 2218WC 06 224WC 57
1224DWR 08 2224BEV 00 2260DC 50
1224R 14 2224FZR
11
2260FZR 57
1224RF
09 2224R 02 2260R 52
1224RSOD 10 2260R 01 2260RDC 51
1224WC 15 2224RG 03 2260WC 53
CLR 1215 18 ADA24R 17
CO 1224F 19