EasyManua.ls Logo

uAvionix echoUAT - Cooling Requirements; Power Wiring

uAvionix echoUAT
55 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
16
UAV-1001006-001
ECCN 7A994
LED Indicator
LED Indication
Solid
LED Indication
Flashing
Red
Fault
Transmitting
Green
Powered
Receiving
6.5 Cooling Requirements
The echoUAT is designed to meet all applicable requirements without
forced-air cooling. Attention should be given to the location of the
installation in order to avoid the transfer of heat into the unit from other
electronic devices to avoid damage to the echoUAT device and voiding the
warranty.
7. Wiring Considerations
7.1 Power Wiring
There are technical benefits for using twisted, shielded wiring for the
echoUAT installation including improved electromagnetic emissions and
susceptibility. Aviation grade wire is recommended to interface the
echoUAT to the aircraft systems. A 3A circuit breaker may be used when
echoUAT and SkyFYX power inputs are combined on the same circuit.
The maximum distance between the echoUAT and the DC power source is
determined by the wire resistance; IE the voltage drop across the power
source to the EchoUAT unit. The echoUAT requires a resistance of less
than 0.5 ohms in the power line for satisfactory operation. The following
table provides guidance for a typical aircraft wiring.
Gauge
ohm/km
Length for 0.5ohm
20 AWG
35
14.2m
22 AWG
64
7.8m
24 AWG
99
5.0m
1.2