UP240AC Plus: 2X120W or 4X60W AC/DC Multi Charger
Question and Answer IconNeed help?

Do you have a question about the Ultra Power UP240AC Plus and is the answer not in the manual?

Ultra Power UP240AC Plus Specifications

General IconGeneral
BrandUltra Power
ModelUP240AC Plus
CategoryBattery Charger
LanguageEnglish

Summary

WARNING AND SAFTEY NOTE

Unsupervised Operation and Malfunction

Never leave the charger unsupervised; terminate process immediately if malfunction is found.

Battery Specification Verification

Ensure battery specifications meet charger requirements to prevent damage or fire.

Connection Sequence

Connect charge cable to charger first, then battery, to avoid short circuits.

Prohibited Battery Types

Do not charge mixed cell types, fully charged, non-rechargeable, or faulty batteries.

SPECIAL FEATURES

Optimized Operating Software

Features AUTO function for safe charging/discharging, preventing overcharging and malfunctions.

LITHIUM BATTERY CONNECTION DIAGRAM

Power-On Before Connection

Charger MUST be powered before connecting battery to prevent failure or damage.

Parameter Verification

Essential to check charging parameters and polarity before connecting any battery.

Charge Lead Connection

Connect charge leads to charger first, then battery, to avoid short circuits.

Balance Socket Connection

Connect balance wire to the charger with correct polarity (black wire to negative marking).

PROGRAM FLOW CHART

Lithium Battery Programs

Flow charts for LiPo, Lilo, LiFe, LiHV - BALANCE, CHARGE, FAST CHG, STORAGE, DISCHARGE.

LITHIUM BATTERY PROGRAMS

Charging at Balance Mode

Balances individual cell voltages during charging for equalization.

Balance Mode Operation

Connect battery's power lead and balance wire; processor monitors and controls charging current per cell.

PB BATTERY PROGRAM

NIMH/NICD BATTERY PROGRAM

BATTERY MEMORY SET

SYSTEM SET UP

WARNING AND ERROR MESSAGE

Reverse Polarity Warning

Indicates incorrect polarity connection.

Connection Errors

Covers connection breaks, main port errors, and balance connection errors.

Voltage Errors

Cell voltage too low, too high, or invalid; incorrect cell number.

Temperature Warnings

Internal or external temperature goes too high.

Capacity/Time Limit Warnings

Over charge capacity limit or over time limit reached.