Do you have a question about the Ultra Power B6 mini and is the answer not in the manual?
Circuit Power (Max. Charge) | 60W |
---|---|
Charge Current Range | 0.1-6.0A |
Discharge Current Range | 0.1-2.0A |
Current Drain for Balancing LiPo | 300mA/cell |
NiCd/NiMH Battery Cell Count | 1-15 cells |
LiPo/LiIon/LiFe Battery Cell Count | 1-6 cells |
Pb Battery Voltage | 2-20V |
Weight | 133g |
Dimensions | 76x56x31mm |
Maximum Discharge Power | 5W |
Operating Voltage Range | 11.0-18.0V DC |
Battery Types | LiPo, LiIon, LiFe, NiMH, NiCd, Pb |
Details the technical specifications of the B6 mini charger, including input voltage, power, current ranges, and dimensions.
Highlights the AUTO function for automatic current setting and safety features like malfunction detection and circuit disconnection.
Explains the charger's built-in individual-cell voltage balancer, eliminating the need for an external balancer.
Describes how the charger monitors and balances individual cells during battery discharging, alerting for abnormalities.
States the charger's compatibility with various lithium battery types including LiPo, Lilon, LiFe, and LiHV.
Details the 'fast' charge mode for reduced charging time and 'store' mode for preserving battery health during long-term storage.
Explains the cyclic charge/discharge feature for battery refreshing and balancing, allowing 1 to 5 cycles.
Describes the 'Re-Peak' mode for NiMH/NiCD batteries, allowing multiple peak charges to ensure full charge and assess fast charge performance.
Allows storage and recall of up to 10 charge/discharge profiles for user convenience and quick setup.
Enables the user to adjust the charger's end voltage for specific battery requirements.
Allows the user to check the total voltage, highest, lowest, and individual cell voltages of a LiPo battery.
Explains the Delta-peak sensitivity for NiMH/NiCd batteries, automatically terminating charging when voltage exceeds a threshold.
Allows setting an upper limit for charging current, particularly useful for low-impedance NiMH batteries in AUTO mode.
Automatically stops charging when the total charging capacity (current x time) reaches a user-defined limit.
Terminates the process if the battery temperature reaches a critical limit, requiring an optional temperature probe.
Allows setting a maximum duration for the charging or discharging process to prevent defects.
Provides essential steps and warnings for correctly connecting a battery to the charger, emphasizing correct parameter settings and connection order.
Details the connection of the balance wire to the charger, stressing the importance of correct polarity alignment with the negative marking.
Explains the balance mode for lithium batteries, focusing on monitoring and equalizing cell voltages during charging via the balance wire.
Details the normal charging mode for LiPo/LiFe/Lilon/LiHV batteries, recommending balance lead use for optimal results.
Details the charging process for Pb lead-acid batteries, specifying current limits and voltage matching with the battery being charged.
Explains how to discharge Pb lead-acid batteries, setting discharge current and nominal voltage, and recommending voltage matching.
Covers charging NiMH/NiCD batteries for R/C models, including parameter adjustment and storing values.
Describes the 'Auto Charge' mode, where the charger automatically detects and charges NiMH/NiCD batteries, with adjustable current limits.
Explains the 'Re-Peak' charge mode for NiMH/NiCD batteries, allowing multiple peak charges for optimal battery conditioning.
Details the process for discharging NiMH/NiCD batteries, including setting discharge current and final voltage.
Illustrates setting up and saving battery parameters for Lipo battery pack (2S/7.4V) including voltage, current, and discharge voltage.
Allows adjustment of the terminal voltage, with a range of 4.18-4.30V, for specific battery requirements.
Enables setting the cut-off temperature for the charger, adjustable between 20°C and 80°C.
Describes the process of saving configured battery programs by pressing START/ENTER for over 3 seconds.
Shows how to load a saved battery profile by pressing START/ENTER, or enter setting mode if not loaded.
Allows the user to enter the Lithium Battery Meter program to check individual cell and total battery voltages.
Initiates the system setup process, allowing users to adjust default settings for parameters like rest time and safety time.
Sets a time delay between charge/discharge cycles to allow the battery to cool down, with values ranging from 1 to 60 minutes.
Activates an integral safety timer to prevent overcharging, especially for faulty batteries or when termination circuits fail.
Sets the maximum charge capacity to prevent overcharging, automatically stopping the process at the selected value.
Enables audible beeps for button presses and mode changes, providing feedback to the user.
Monitors input battery voltage and terminates operation if it drops below a set threshold to protect the input battery.
Restores the charger to its factory default settings by pressing the Start/Enter button for over 3 seconds.
Displays the current software version of the charger.
Indicates the final voltage reached when a charging program has ended.
Shows the current input voltage supplied to the charger.
Displays both the external temperature of the unit and the internal temperature of the battery.
Indicates the status and duration of the safety time feature.
Shows the status and set value for the capacity cut-off function.