Safety Information
Before using the meter for the first time, please read the safety information
and operating instructions carefully.
Use the meter only as specified in this manual. Otherwise, it may cause
damage to the meter, affect measurement accuracy and result in personal
injury.
Do not disassemble or repair the meter without authorization. Do not refit
or change the performance of the laser transmitter illegally. Please keep
the meter properly, do not place it where children can reach it, and avoid
use by irrelevant personnel.
Do not irradiate the laser at eyes and other parts of the body , and on the
surface of highly reflective objects.
The electromagnetic radiation of the meter may cause interference to other
equipment. Please do not use the meter near airplanes, medical equipment
or in flammable and explosive environments.
The replaced batteries and discarded meters cannot be disposed of together
with domestic garbage. Please dispose of them in accordance with
relevant national or local laws and regulations.
If the meter has any quality problems, or if users have any questions about
the use of the meter, please contact the local dealer or manufacturer in time.
Battery status
Data storage
Laser indication
Max
Length measurement
Area/volume/triangle
measurement
Min
Secondary display
Primary display
Product Introduction
Display
Keypad
On/measure
Subtract/sound
Add
Area/volume/triangle
Measurement reference/
unit selection
Off/clear
Log
1. Open the battery door on the back of the meter, install the battery according
to the polarity instructions, and close the battery door.
2. The meter can only use 1.5V AAA alkaline batteries.
3. When the meter is not used for a long time, please take out the battery to
prevent it from corroding the meter's main body.
Batteries
Power On and Function Settings
1. Power On/Off
In the shutdown state, press , the meter and the laser will be started
at the same time.
In the power-on state, press and hold for 3 seconds to turn off the
meter. If no operation is performed within 150 seconds, the meter will
automatically shut down.
2. Unit Settings
Long press to enter the unit setting state and the current unit can be
reset. The default unit of the meter is 0.000m. There are 6 optional units.
Measurement units:
Length Area Volume
3. Measurement Reference Settings
Short press to measure from front or end. The default setting is end
measurement.
4. Backlight
The backlight is automatically turned on and off. It will turn on for 15 seconds
when any button is pressed. The backlight will automatically turn off if there
is no operation after 15 seconds to save power.
5. Sound
Long press to turn on or off the sound of the beeper.
6. Self-Calibration
Self-calibration function can ensure the measurement accuracy.
Calibration method: In the shutdown state, press and hold , and then
short press to turn on the meter. When the screen shows ' ' with a
flashing number at the bottom, the meter enters the self-calibration mode.
At this time, users can press to calibrate values according to the error
of the meter.
Calibration range: -9~9mm
Examples: The actual distance is 3.780m.
If the measured value is 3.778m, which is 2mm smaller than the actual value,
press + to increase the calibration value by 2mm.
If the measured value is 3.783m, which is 3mm larger than the actual value,
press to lower the calibration value by 3mm.
After adjustment, press to save the calibration results.
Measurement Modes
1. Single Measurement
While the meter is on, press to transmit the laser. Press again to make
the distance measurement. The measurement results will show on the
primary display.
2. Continuous Measurement
While the meter is on, long press to enter the continuous measurement
state. The maximum and minimum values during the measurement will show
on the secondary display. The measurement results will show on the primary
display. Short press or to exit the continuous measurement.
3. Area Measurement
Press FUNC 1x. The symbol will appear on the display and one side of
the rectangle will flash.
Press to make the first measurement (length).
Press again to make the second measurement (width).
The meter will automatically calculate the area, and the result will show on
the primary display. The length and width will show on the secondary display.
During the measurement process, press to clear the measurement result
and re-measure.
Press to exit the area measurement and enter the length measurement
mode.
4. Volume Measurement
Press FUNC 2x. The symbol will appear on the display.
Press to make the first measurement (length).
Press again to make the second measurement (width).
Press again to make the third measurement (height).
The meter will automatically calculate the volume, and the result will show
on the primary display. The length, width and height will show on the secondary
display.
During the measurement process, press to clear the measurement result
and re-measure.
Press to exit the volume measurement and enter the length measurement
mode.
5. Indirect Measurement
The meter has four modes that use the Pythagorean theorem to measure
the distance of one side of a triangle, which is convenient for users to perform
indirect measurement in a complex environment.
Question and Answer IconNeed help?

Do you have a question about the UNI-T LM50A and is the answer not in the manual?

UNI-T LM50A Specifications

General IconGeneral
ModelLM50A
CategoryMeasuring Instruments
TypeLaser Distance Meter
Accuracy±2mm
DisplayLCD
Auto Power OffYes
Automatic shutdown3 minutes
Automatic laser shutdown30 seconds
Operating Temperature0°C to 40°C
Measurement Unitsm, in, ft
Laser ClassClass 2
Power Source2 x AAA batteries
Measuring Range0.05m to 50m
Storage Temperature-20°C to 60°C

Summary

Safety Information

General Safety Precautions

Covers safe usage, prohibited actions, laser safety, electromagnetic interference, battery disposal, and support contact.

Product Introduction

Display Overview

Details battery status, data storage, laser indication, primary and secondary displays.

Keypad Functions

Explains buttons like On/measure, Subtract/sound, Add, FUNC, CLEAR, UNIT, and OFF.

Battery Installation

Instructions for installing 1.5V AAA alkaline batteries and precautions for long-term storage.

Power On and Function Settings

Power OnOff and Auto Shut-down

How to power the meter on/off and its automatic shut-down feature.

Unit Settings

Procedure to enter unit setting state and reset the default unit.

Measurement Reference Settings

How to switch between front and end measurement references.

Backlight Control

Automatic backlight activation and deactivation based on button presses.

Sound Control

How to turn the beeper sound on or off using a long press.

Self-Calibration Procedure

Steps for self-calibration to ensure measurement accuracy using specific button presses.

Measurement Modes

Single Measurement

Basic distance measurement by pressing the measure button.

Continuous Measurement

Measure continuously and view max/min values by long-pressing the measure button.

Area Measurement

Measures area by inputting length and width, showing results on primary display.

Volume Measurement

Calculates volume using length, width, and height inputs.

Indirect Measurement

Uses Pythagorean theorem for measuring distances in complex environments.

Advanced Measurement Functions

Addition and Subtraction

Adds or subtracts single distance, area, or volume measurements.

Data Storage

Stores current measurement data by pressing and holding a button.

View and Delete Data

Queries stored data, scrolls through records, and deletes current or all records.

Specifications and Maintenance

Product Specifications

Lists measurement range, accuracy, units, laser class, power, and dimensions.

Error Codes

Details common error codes and their resolutions for troubleshooting.

Maintenance and Care

Guidance on cleaning, avoiding harsh environments, and battery removal.

Packing List

Lists all accessories included with the meter, such as carrying bag and user manual.