Type | Digital Multimeter |
---|---|
Display | LCD |
Max DC Voltage | 600V |
Max AC Voltage | 600V |
Max Current | 10A |
Resistance Range | 600Ω/6kΩ/60kΩ/600kΩ/6MΩ/60MΩ |
Capacitance Range | 6nF/60nF/600nF/6μF/60μF/600μF/6mF/60mF |
True RMS | Yes |
Auto Range | Yes |
NCV (Non-Contact Voltage Detection) | Yes |
Analog Bar Graph | Yes |
Diode Test | Yes |
Continuity Buzzer | Yes |
Continuity Test | Yes |
Data Hold | Yes |
Relative Mode | Yes |
MAX/MIN | Yes |
Backlight | Yes |
Input Protection | Yes |
Safety Rating | CAT III 600V |
DC Current Range | 600μA/6000μA/60mA/600mA/10A |
AC Current Range | 600μA/6000μA/60mA/600mA/10A |
Frequency Range | 10Hz - 10MHz |
Duty Cycle | 0.1% to 99.9% |
Temperature | -40°C - 1000°C |
Details the key functionalities and advanced features of the UT117C multimeter.
Lists the standard and optional accessories included with the multimeter.
Outlines critical safety precautions and warnings for using the multimeter.
Explains the various electrical symbols used on the multimeter and in the manual.
Describes the general specifications, performance, and environmental conditions of the device.
Identifies and describes the physical components and parts of the multimeter.
Explains the function and positions of the multimeter's rotary switch for selecting modes.
Details the function of each button on the multimeter and their operations.
Provides a breakdown and explanation of the symbols and indicators on the multimeter's LCD screen.
Instructions for measuring AC/DC voltage automatically using the Auto-V LoZ function.
Steps for measuring AC and DC voltage, including using the LPF function.
How to measure low AC and DC voltages (millivolts) using the multimeter.
Procedure for checking electrical continuity in circuits using the multimeter.
Instructions on how to measure electrical resistance accurately with the multimeter.
Steps for testing diodes to check their functionality using the multimeter.
Guide on measuring capacitance values of electronic components with the multimeter.
How to use an external current probe for ACA/DCA measurements with the multimeter.
Instructions for measuring AC and DC current directly using the multimeter's terminals.
How to perform non-contact detection of AC voltage using the NCV function.
How to enable or disable the audible buzzer for silent operation.
Instructions to disable the automatic backlight turn-off feature.
How to disable the automatic power-off function of the multimeter.
Information on how to wake the multimeter from sleep mode.
Details the multimeter's audible and visual alarm system for different measurements.
Technical specifications for the Auto-V LoZ voltage measurement function.
Technical specifications for DC voltage measurements.
Technical specifications for AC voltage measurements, including frequency response.
Technical specifications for the Low Pass Filter (LPF) function for AC voltage.
Technical specifications for frequency measurement functions.
Technical specifications for DC current measurements.
Technical specifications for AC current measurements.
Technical specifications for resistance measurements.
Technical specifications for capacitance measurements.
Technical specifications for continuity testing.
Technical specifications for diode testing.
An introduction to the Bluetooth software and its compatibility.
Instructions on how to download and install the iDMM2.0 mobile application.
Guidance on connecting and using the Bluetooth software with the multimeter.
Steps for uninstalling the mobile application from a device.
Description of the magnetic hanger and its key features.
Instructions for installing the magnetic hanger onto the multimeter.
Practical applications and ways to use the magnetic hanger with the multimeter.
Routine maintenance procedures to keep the multimeter in good condition.
Step-by-step instructions for replacing the battery and fuse.