UT131 Palm Size Multimeter
-31-
0.1Ω
Set Value:
Open circuit: resistance≥50Ω, no beep.
Well connected circuit: resistance≤10Ω, continuous beeps.
0.001V
Open circuit voltage :2.1V , test current: about 1mA
Silicon PN junction voltage: 0.5 ~ 0.8V.
Overload protection: 250Vrms(AC/DC)
5. Capacitance(only for UT131A)
Range
Resolution
Accuracy
2.000nF 0.001nF Under REL mode±(5%+5)