EasyManua.ls Logo

UNI-T UT15B PRO - Page 4

UNI-T UT15B PRO
17 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
UT
15
B
PRO
/
UT
17
B
/
UT
18
B
PRO
User
Manual
UT
15
B
PRO
/
UT
17
B
/
UT
18
B
PRO
User
Manual
III
.
Accessories
Open
the
package
and
check
the
below
items
,
if
any
is
missing
or
damaged
,
please
contact
your
supplier
immediately
:
1
.
User
manual
2
.
Test
leads
3
.
Point
K
-
type
(
Ni
-
Cr
~
Ni
-
Si
)
thermocouple
4
.
Thermocouple
adapter
5
.
Battery
2
.
Safety
Instruction
A
Warning
To
ensure
safe
operation
and
service
of
the
tester
,
follow
these
instructions
.
Failure
to
observe
these
warnings
can
result
in
severe
injury
.
1
)
Do
not
use
the
meter
without
having
rear
cover
in
place
or
electric
shock
may
occur
.
2
)
Check
the
test
leads
before
use
to
see
if
they
appear
to
be
damaged
.
3
)
When
the
a
icon
shows
on
LCD
,
please
replace
the
battery
in
time
to
ensure
accuracy
.
4
)
The
function
selection
knob
should
be
adjusted
to
right
scale
.
5
)
The
measured
signal
is
not
allowed
to
exceed
the
specified
range
to
avoid
damage
or
electric
shock
.
6
)
It
is
forbidden
to
switch
scale
during
measurement
or
damage
may
occur
.
7
)
After
measuring
operation
,
disconnect
test
leads
and
the
circuit
;
after
the
current
measurement
,
especially
for
strong
current
,
it
is
necessary
to
power
off
before
disconnecting
test
leads
and
circuit
.
8
)
Use
caution
when
working
with
voltages
above
AC
30
Vrms
or
DC
60
V
.
Such
voltages
pose
a
shock
hazard
.
9
)
Do
not
use
the
multimeter
in
extremely
high
-
temperature
or
high
-
humidity
environment
,
particularly
in
the
damp
environment
in
where
the
product
performance
may
be
severely
degraded
.
10
)
Do
not
change
the
internal
circuit
of
the
meter
to
avoid
damage
to
the
meter
and
user
!
11
)
Clean
the
meter
casing
with
damp
cloth
and
mild
detergent
.
Do
not
use
abrasives
or
solvents
!
12
)
Before
use
verify
tester
operation
by
measuring
a
known
voltage
that
is
within
the
rating
of
this
unit
.
13
)
If
use
the
meter
without
following
up
the
operating
instructions
,
the
protection
provided
by
the
meter
may
be
impaired
or
lost
.
14
)
Use
of
test
leads
:
Probe
assemblies
to
be
used
for
MAINS
measurements
shall
be
RATED
as
appropriate
for
MEASUREMENT
CATEGORY
II
or
III
or
IV
according
to
IEC
61010
-
031
and
shall
have
a
voltage
RATING
of
at
least
the
voltage
of
the
circuit
to
be
measured
.
1
pc
1
pair
1
pc
(
UT
17
B
PRO
/
UT
18
B
PRO
)
1
pc
(
UT
17
B
PRO
/
UT
18
B
PRO
)
1
pair
IV
.
Safety
Instruction
1
.
Safety
Certifications
1
)
CE
,
cETLus
certification
:
EN
61326
-
1
:
2013
;
EN
61326
-
2
-
2
:
2013
EN
61010
-
1
:
2010
+
A
1
:
2019
;
EN
61010
-
2
-
030
:
2010
;
EN
61010
-
2
-
033
:
2012
2
)
For
UT
15
B
PRO
/
UT
17
B
PRO
:
CAT
III
1000
V
CAT
IV
600
V
For
UT
18
B
PRO
:
CAT
II
1000
V
CAT
III
600
V
3
)
Pollution
degree
:
2
4
)
Safety
standards
:
double
insulation
6
5

Related product manuals