UT
15
B
PRO
/
UT
17
B
/
UT
18
B
PRO
User
Manual
UT
15
B
PRO
/
UT
17
B
/
UT
18
B
PRO
User
Manual
XI
.
Measurement
Operation
Instruction
MAX
button
(
UT
15
B
PRO
)
:
press
to
enter
manual
range
mode
and
display
the
maximum
value
.
To
exit
MAX
/
MIN
measurement
mode
,
press
this
button
for
over
2
seconds
or
switch
the
knob
.
(
Only
suitable
for
V
~
,
V
,
m
VS
,
Q
)
MIN
button
(
UT
15
B
PRO
)
:
press
to
enter
manual
range
mode
and
display
the
minimum
value
.
To
exit
MAX
/
MIN
measurement
mode
,
press
this
button
for
over
2
seconds
or
switch
the
knob
.
(
Only
suitable
for
V
~
,
V
,
mV
£
,
Q
)
REL
button
:
press
to
save
the
first
measured
value
as
reference
,
then
input
again
,
the
displayed
value
is
the
different
value
between
current
measured
value
and
the
reference
value
,
press
it
again
to
exit
relative
measurement
mode
.
(
Only
suitable
for
V
~
,
V
,
mV
£
,
IS
5
,
Q
,
Hf
-
)
.
Long
press
to
enter
or
exit
this
function
for
UT
18
B
PRO
.
Hz
/
%
button
(
UT
17
B
PRO
/
UT
18
B
PRO
)
:
under
voltage
and
current
measurement
mode
,
press
this
button
to
switch
to
frequency
or
duty
ratio
measurement
mode
.
SELECT
button
:
press
to
select
functions
(
only
suitable
for
multi
-
range
)
.
Under
AC
voltage
mode
,
press
this
button
will
display
VFC
and
enter
Variable
Frequency
Filter
measurement
mode
,
which
can
measure
variable
frequency
voltage
stably
,
press
this
button
again
to
exit
VFC
measurement
mode
.
HOLD
button
(
suitable
for
full
range
)
:
Press
to
lock
hold
the
displayed
value
,
and
LCD
will
display
m
symbol
,
press
it
again
to
relieve
and
enter
the
normal
measurement
mode
.
BL
button
(
-
#
)
:
press
to
turn
on
/
off
the
background
light
sensing
function
.
LIGHT
button
(
)
:
turn
on
or
off
the
flashlight
lighting
function
.
Check
the
built
-
in
AA
1.5
Vx
2
batteries
,
the
a
symbol
will
be
displayed
if
the
battery
is
low
and
needs
to
be
replaced
in
time
,
which
.
With
the
symbol
of
A
.
displaying
,
please
notice
that
the
measuring
voltage
or
current
shall
not
exceed
the
specified
value
in
order
to
ensure
safety
!
1
.
AC
Voltage
Measurement
(
Figure
3
)
1
)
Turn
the
function
selection
knob
to
the
AC
voltage
scale
.
2
)
Insert
the
red
test
lead
to
V
port
and
the
black
one
to
the
COM
port
,
and
connect
the
tips
of
two
test
leads
to
both
ends
of
measuring
voltage
separately
(
with
the
load
in
parallel
)
to
measure
.
3
)
When
the
input
impedance
of
the
meter
is
about
10
MQ
,
the
load
may
cause
measurement
error
in
circuit
with
high
impedance
.
In
most
cases
,
if
the
circuit
impedance
is
under
10
kQ
,
error
can
be
ignored
(
0.1
%
or
lower
)
.
4
)
Press
SELECT
button
in
ACV
mode
to
enter
the
VFC
Variable
Frequency
Filter
mode
,
then
the
high
frequency
interference
signal
will
be
filtered
out
through
internal
specific
filter
circuit
to
ensure
the
accuracy
.
It
can
be
applied
in
VFC
frequency
conversion
voltage
.
5
)
The
AC
measurement
value
is
true
RMS
value
.
r
\
j
HwRHS
8000
Count
*
M
8
UB
KIEL
tSGDEDE
*
Figure
3
14
13