II. OOBA (Out-of-Box Audit)
Open the packing box and take out the instrument. Please
carefully check whether or not the following accessories
are missing or damaged. If you find any missing or damage,
please contact the supplier immediately.
1. Instructions ………………………….. one copy
2. AAA battery 1.5V. …………………… two pieces
3. Probe ………………………………….. one pair
4. Temperature probe …………………. one pair
Ill. Safety Instructions
The instrument is designed in conformity with CE certification, EN 61010-1, 61010-2-032 and 61010-2-033 of EU
(pollution level 2), measurement category CAT II 600V
and CAT Ill 300V as well as double insulation safety standard. Before using, please read the operation instruction
and follow all safety instructions:
Conforms to UL STD. 61010-1, 61010-2-032, 61010-2-033 Certified to CSA STD. C22.2 NO. 61010-1, IEC STD
61010-2-032, 61010-2-033 CAT II: Applicable to test and measuring circuits connected direcliy to utilization points
(socket outlets and similar points) of the low-voltage MAINS installation. CAT Ill: Applicable to test and measuring
circuits oonnected to the distribution part of the building’s low-voltage MAINS installation, before use and follow all
safety instructions.
1. Please follow the operation instruction to use clamp meter, otherwise, the protection provided by the instrument
is likely to be weaken.
2. Abide by the national laws and regulations; personal protective equipment must be applied to prevent from the
injury caused by electric shock, arc discharge and so on, when working in the environment with bare live wire.
3. Please do not reach beyond any position outside the protective shield of the current clamp meter.
4. Before each use, check whether there are cracks or damages on the shell of current clamp meter and the
output cable and whether there is any part under poor connection, and pay attention to the insulation layer
surrounding the clamp mouth.
5. Before removing the battery cover, please make sure to remove the clamp meter from all live circuits, and
disconnect the leading wire.
6. lt is prohibited to use this clamp meter on circuit with voltage of higher than 600V (CATll600V), or frequency of
above 400Hz
7. ?.Measurement category classification standard CAT II 600V CAT Ill 300V and pollution level 2 must not be
violated.
8. Be sufficiently careful when working in the environment with bare wires, for contacting with wires might lead to
electric shock.
9. Special attention shall be paid to 60V DC (direct current), 30V AC (alternating current effective value) or 42V
AC (peak value), because there is risk of electric shock.
10. If probe needs to be replaced, ones with the same CAT II 600V CAT Ill 300V level according to IEC 61010-031
shall be adopted.
11. Before measuring, function switch must be placed at the correct position and tap positions are not permitted to
be switched during measurement, so as to prevent the instrument
from damage.
12. Before it is used in high voltage circumstance, it is necessary to measure the known voltage, such as socket for
civil use, to confirm validity of the instrument and prevent misleading
of damaged instrument.