31
ENGLISH
Maintenance instructions
ATTENTION!
Some service parameters can be edited
from the control panel:
x 10’’
service
MAX
M
I
N
service
MAX
M
I
N
service
MAX
M
I
N
service
OK
1 ACTIVATION
By pressing the button (D) for 10 seconds, the
function is activated when the key ashes on the
display
VALUES
FROM A DEFAULT
0 (Min) 99 (Max) 99
VALUES
FROM A DEFAULT
0 (- 20°C) + 10°C) 20 (0°C)
VALUES
FROM A A DEFAULT
0 (*) 1 (minute)
(minutes)
0
(*) WITH VARIABLE HYSTERESIS
PUMP POST CIRCULATION
VALUES
FROM A DEFAULT
0 (5 min) 1 (ALWAYS) 0 (5 min)
SELECTION
Turn the HEATING knob ‘’B’’
Turn the DOMESTIC HOT WATER knob ‘’C’’
The value ashes on the display
CONFIRM SELECTION
Conrm the parameter to be edited by pressing
the unblock key
CONFIRM VALUE
Conrm the value by pressing the unblock key
PARAMETER SELECTION
Go back to section 2.
DISABLING
To exit the parameters list
wait for 20” or quickly turn
the domestic hot water
knob ‘‘C’’.
2