Unical DUA plus - Operational Data; General Specifications

Unical DUA plus
32 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
8
General information
II2H3+
7,8
0,5
3
3,5
85
45 T (35 E)
7
160,9
0,5
6
11
10
7,4
8,3
9,5
11,1
13,7
35 - 60
230/50
4
137
X4D
45
l/min
bar
bar
l
°C
°C
l
l
bar
bar
l/min.
l/min.
l/min.
l/min.
l/min.
l/min.
l/min.
°C
V-Hz
A (F)
W
IP
kg
kW
kW
%
%
%
%
n.
%
%
%
°C
g/s
%
%
mg/kWh
%
%
24,00
11,1
90,04
89,76
88,61
87,14
93,59
90,31
1,79 - 3,55
60,9 - 77,7
17,49 - 20,18
117,89
2,5 - 5,1
134
3
9,69 - 6,41
0,446
II2H3+
7,8
0,5
3
3,5
85
45 T (35 E)
7
160,9
0,5
6
11
10
7,4
8,3
9,5
11,1
13,7
35 - 60
230/50
4
90
X4D
42
DUA plus
CTFS 24 - RTFS 24
DUA plus
CTN 24 - RTN 24
24,79
11,03
92,86
92,79
90,47
90,18
94,33
90,07
1,82 - 1,47
76,4 - 94,1
14,10 - 14,66
54,56
3,1 - 7,3
164
2
9,93 - 5,67
0,535
DUA plus
CTFS 24 - RTFS 24
DUA plus
CTN 24 - RTN 24
1.4 - OPERATIONAL DATA
For some data (NOZZLES - BURNER GAS PRESSURE - DIAPHRAGMS - INPUTS - GAS CONSUMPTIONS)
refer to paragraph ADAPTATION TO THE USE OF OTHER GAS on page 23.
1.5 - GENERAL SPECIFICATIONS
(*) Warning: The utilisation of this type of boilers in the "floor heating systems" needs the use of specific equipments (e.g.:
UNICAL Thermic Module) to avoid all risks of smoke condensation within the boiler.
Nominal output
Minimum output
Actual water efficiency at 100 % of nominal load
Minimum water efficiency required at 100 % of nominal load
Actual water efficiency at 30 % of nominal load
Minimum water efficiency required at 30 % of nominal load
Star number (according to Efficiency Directive 92/42/CE)
Combustion efficiency at 100 % of nominal load
Combustion efficiency at minimum load
Heat losses through the casing (min. / max.)
Maximum net smoke température (Ts- Ta)
Massive smoke flow rate (min. / max.)
Air exces (lambda)
CO
2
NOx (ponderal value according to EN 297/A3+EN 483)
NOx class (ponderal value according to EN 297/A3 + EN 483)
Chimney heat losses with burner in operation (min./max.)
Chimney heat losses with burner shut-off
Boiler category
Minimum water low rate in heating circuit (ΔT 20°C)
Minimum pressure in heating circuit
Maximum pressure in heating circuit
Water content of the primary circuit
Maximum operation temperature in heating mode
Minimum operation temperature in heating mode (*)
Expansion vessel total content
Maximum water content of the heating circuit (max. temp. 90°C)
Minimum pressure in the D.H.W. circuit
Maximum pressure in the D.H.W. circuit
Specific D.H.W. flow rate ( t 30°C according to EN 625)
Flow rate of the D.H.W. flow restrictor
Contiunuous D.H.W. production with t 45 K
Contiunuous D.H.W. production with t 40 K
Contiunuous D.H.W. production with t 35 K
Contiunuous D.H.W. production with t 30 K
Contiunuous D.H.W. production with t 25 K
D.H.W. temperature adjustable between
Electrical power supply Tension/Frequency
Supply fuse
Maximum absorbed output
Insulation degree
Net weight (dry)

Related product manuals