EasyManua.ls Logo

Unigas G400A - PART II: INSTALLATION (Continued); Configuration with separate electrical panel (optional)

Default Icon
128 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
PART II: INSTALLATION
26
1. Inlet G1/2
2. To the nozzle G1/2
3. Return G1/2
4. Pressure gauge port G1/4
5. Vacuum gauge port G1/4
6. Pressure governor
Connecting the oil flexible hoses to the pump
To connect the flexible oil hoses to the pump, proceed as follows, according to the pump provided:
1 remove the closing nuts A and R on the inlet and return connections of the pump;
2 screw the rotating nut of the two flexible hoses on the pump being careful to avoid exchanging the lines: see the arrows marked
on the pump.
For further information, refer to the technical documentation of the pump.
.
Diesel filters
Suntec TA..
Oil viscosity 3 ÷ 75 cSt
Oil temperature 0 ÷ 150°C
Min. suction pressure - 0.45 bar to avoid gasing
Max. suction pressure 5 bar
Max. return pressure 5 bar
Rotation speed 3600 rpm max.
Suntec T+TV Suntec TA
R
A
R
A
Item Note Connection Max. operating
pressure
Max. operating
temperature
Filtering
degree
Protec-
tion
5 20151PE (*)
-
3/8” 1 bar -20, 60 °C
100 μ
-
6 20201PL (*)
-
3/8” 1 bar -20, 60 °C
100 μ
-
7 GA70501
-
1” 4 bar 90 °C
100 μ
IP65
(*) Supplied per pilot diesel fuel if present