Functionality
Symbologies
Code 39, Full ASCII Code39, Interleave 2 of 5, UPC
A/E/E1, MSI, Codabar, Code 11, EAN8/13, Code 93,
Code 128, EAN128, Code32, GS1 databar Code,
Bookland EAN, Discreate 2 of 5, Chinese 2 of 5, ISBT
128, UCC Coupon Extended Code, Bookland 128
Operation Mode Trigger mode, Pulse mode, Flash mode, Continuous Mode
Data Formatting Prefix, Suffix, Code ID, Reformatting Date
Electrical
Operation Voltage 4 VDC to 5.5 VDC
Current Consumption
Operation mode: <110mA,
Standby mode: <20mA
Indicator
Direct decode indicator, good decode
LEDs, beeper (adjustable tone/volume)
Environmental
ESD Protection Functional after 8K Contact and 15K Air
Mechanical Shock 2M onto concrete (scanner only)
Operating Temperature -10°C to 50°C (14°F to 122°F)
Storage Temperature -40°C to 70°C (-40°F to +158°F)
Relative Humidity 95% non-condensing
IP Rating IP42
RegulatoryApprovals
CE, FCC, BSMI, VCCII