EasyManua.ls Logo

United States Stove King - User Manual

United States Stove King
48 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
851641T-0504j
King/Ashley Pellet Stove
Models 5500/5500M
5500M
5500XL
5500
5500M
5500XL
5500
R
Report #: F20-570
CALIFORNIA PROPOSITION 65 WARNING:
This product can expose you to chemicals including carbon monoxide, which
is known to the State of California to cause cancer, birth defects and/or other
reproductive harm. For more information, go to www.P65warnings.ca.gov
Ce produit peut vous exposer à des agents chimiques, y compris au monoxyde de
carbone, lesquels sont reconnus dans l’État de la Californie comme causant le cancer et
des malformations congénitales ou autres dommages au fœtus. Pour obtenir plus de
renseignements, veuillez consulter le site www.P65warnings.ca.gov
SAVE THESE INSTRUCTIONS
THIS MANUAL WILL HELP YOU TO OBTAIN EFFICIENT, DEPENDABLE
SERVICE FROM THE HEATER, AND ENABLE YOU TO ORDER REPAIR PARTS
CORRECTLY. KEEP IN A SAFE PLACE FOR FUTURE REFERENCE.
Please read this entire manual before installation and use of this
appliance. Failure to follow these instructions could result in property
damage, bodily injury, or even death.
Contact your local building or re ofcials about obtaining permits,
restrictions and installation inspection requirements in your area.
If your heater is not properly installed, a house re may result. For
everyone’s safety, follow all Installation and Operating Directions.
Never use makeshift compromises during the installation of this
appliance. Contact your local building or re ofcials about
restrictions and installation inspection requirements in your area.
United States Stove Company
227
Industrial Park Rd.,
South Pittsburg, TN 37380
PH: (800) 750-2723
www.usstove.com
This unit is not intended to be used as a
primary source of heat.
Certied to ASTM E1509-12 (2017), and Certied
to ULC S627, 2000, and(UM) 84-HUD
U.S. Environmental Protection Agency
Certied to comply with 2020 particulate
emissions standards.
This manual is subject to change without
notice.
ALL PICTURES SHOWN ARE FOR
ILLUSTRATIVE PURPOSES ONLY. ACTUAL
PRODUCT MAY VARY DUE TO PRODUCT
ENHANCEMENT.

Questions and Answers

  • B
    brianwatsonJul 29, 2025
    What to do if my United States Stove keeps shutting down?
    • D
      dominique64Jul 30, 2025
      If your United States Stove shuts down or the fire goes out, it could be due to several reasons. The burnpot might be running out of fuel, so start by refilling the hopper. Another cause is a loss of draft pressure. Ensure the viewing door is properly closed and sealed; adjust the door catch or replace the door gaskets if needed. Also, check for obstructions in outside connections and clean the exhaust system. Finally, verify that the pressure switch connection to the firebox is clear of ash or obstructions. The auger system may also be jammed, or fuel may be 'bridging' in the hopper, which prevents fuel from flowing into the auger feed system.
  • S
    sarahrobertsAug 7, 2025
    Why United States Stove won't start?
    • A
      Andre SanchezAug 8, 2025
      If your United States Stove isn't starting when you press the 'ON' button, the auto-start igniter may be failing to ignite the fuel. First, turn the stove off, clear any unburnt fuel from the burnpot, and try again. Check the pellet quality; replace them if they are moist, wet, or dirty. A loss of draft pressure could also be the cause, so ensure the viewing door is properly sealed (adjust the door catch or replace gaskets if necessary), check for any obstructions in the outside connections, and clean the exhaust system. Make sure the auto-start igniter isn't blocked by ash or soot. If you cannot visibly see the igniter glowing red during start-up, it might need replacement, or there could be an electrical control system problem.
  • B
    Brittany WilsonAug 18, 2025
    How to fix orange flame in United States Stove?
    • D
      Diana RodriguezAug 18, 2025
      An orange, lazy flame in your United States Stove indicates an air/fuel mixture that's too rich. Begin by cleaning out the burnpot and burnpot housing. Ensure the viewing door is closed and sealed correctly; adjust the door catch or replace door gaskets if necessary. Check that all outside connections are free from obstructions and clean the exhaust system.

Summary

Safety Precautions

Specifications

Heating Specifications

Details on fuel burn rate, burn time, and hopper capacity.

Fuel Considerations

Recommendations for pellet fuel quality and storage.

Safety and EPA Compliance

Compliance with safety standards and EPA emission limits.

Installation

Clearances

Required minimum distances from walls and combustible materials.

Venting Requirements

Guidelines for proper exhaust system installation and type.

Special Mobile Home Requirements

Specific installation rules for mobile homes, including safety.

Understanding Your Stove

Control Panel Overview

Thermostat Hook-Up

Operation

Start-Up Procedure

Step-by-step guide for starting the pellet stove.

Tamper Warning

Warning against altering factory-set burn rate settings.

Shut Down Procedure

Correct method for turning off and shutting down the stove.

Daily Operation

Routine checks and considerations during daily use.

Safety and Convenience Features

Overview of built-in safety switches and controls.

Maintenance

Trouble Shooting

Orange, lazy flame_excessive fuel build-up in the burnpot.

Troubleshooting steps for a low, lazy flame and burnpot fuel buildup.

Fire goes out or stove shuts down.

Diagnosing and resolving issues causing the stove to shut off.

Stove does not start a fire when the ON button is pushed.

Steps to resolve issues with the stove failing to ignite.

Error Codes and Display Indicators

United States Stove King Specifications

General IconGeneral
BrandUnited States Stove
ModelKing
CategoryStove
LanguageEnglish

Related product manuals