EasyManuals Logo

Unitronics UMI-B1 UL Series User Manual

Unitronics UMI-B1 UL Series
140 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #101 background imageLoading...
Page #101 background image
UMI-B1 UL Series Inverter Fault tracking
99
Checking part
Checking item
Checking
method
Criterion
not mean that
there is
something
wrong with the
features.
The lead of the
conductors
Ensure that there is no
distortion or
color-changing of the
conductors caused by
overheating.
Visual
examination
NA
Ensure that there are
no crackles or
color-changing of the
protective layers.
Visual
examination
NA
Terminals seat
Ensure that there is no
damage
Visual
examination
NA
Filter capacitors
Ensure that there is no
weeping,
color-changing,
crackles and cassis
expansion.
Visual
examination
NA
Ensure the safety
valve is in the right
place.
Estimate the
usage time
according to the
maintenance or
measure the
static capacity.
NA
If necessary, measure
the static capacity.
Measure the
capacity by
instruments.
The static
capacity is
above or equal
to the original
value x 0.85.
Resistors
Ensure whether there
is replacement and
splitting caused by
overheating.
Smelling and
visual
examination
NA
Ensure that there is no
offline.
Visual
examination or
The resistors
are in ±10% of

Questions and Answers: