UMI-B1 UL Series Inverter Function parameters
40
Function
code
Name
Detailed instruction of parameters
Default
value
Modify
time
after the running command is given, and the
inverter is in a stand-by state and wait for the
delay time set by P01.23
Setting range: 0.060.0s
P01.24
Delay of
the
stopping
speed
Setting range: 0.0100.0s
0.0s
P01.25
0Hz
output
Select the 0Hz output of the inverter.
0: Output without voltage
1: Output with voltage
2: Output at the DC braking current
0
P02 Group Motor 1
P02.01
Rated
power of
asynchron
ous motor
0.42.2kW (0.5~3HP)
Depend
on model
P02.02
Rated
frequency
of
asynchron
ous motor
0.01HzP00.03
60.00Hz
P02.03
Rated
speed of
asynchron
ous motor
136000rpm
Depend
on model
P02.04
Rated
voltage of
asynchron
ous motor
01200V
Depend
on model
P02.05
Rated
current of
asynchron
ous motor
0.86000.0A
Depend
on model
P02.06
Stator
resistor of
asynchron
ous motor
0.001–65.535Ω
Depend
on model