UMI-B1 UL Series Inverter Function parameters
43
Function
code
Name
Detailed instruction of parameters
Default
value
Modify
coefficient
of motor 1
power
Only impact the displaying value other than
the control performance of the inverter.
Setting range: 0.003.00
P03 Group Vector control
P03.00
Speed
loop
proportion
al gain1
The parameters P03.00P03.05 only apply to
vector control mode. Below the switching
frequency 1 (P03.02), the speed loop PI
parameters are: P03.00 and P03.01. Above
the switching frequency 2 (P03.05), the
speed loop PI parameters are: P03.03 and
P03.04. PI parameters are gained according
to the linear change of two groups of
parameters. It is shown as below:
Output frequency
PI parameters
P03.00, P03.01
P03.03, P03.04
P03.02 P03.05
PI has a close relationship with the inertia of
the system. Adjust on the base of PI
according to different loads to meet various
demands.
The setting range of P03.00 and P03.03: 0
200.0
The setting range of P03.01 and P03.04:
0.00010.000s
The setting range of P03.02: 0.00HzP00.05
The setting range of P03.05: P03.02P00.03
20.0
P03.01
Speed
loop
integral
time1
0.200s
P03.02
Low
switching
frequency
5.00Hz
P03.03
Speed
loop
proportion
al gain 2
20.0
P03.04
Speed
loop
integral
time 2
0.200s
P03.05
High
switching
frequency
10.00Hz
P03.06
Speed
loop output
filter
08 (corresponds to 02
8
/10ms)
0
P03.07
Compensa
tion
coefficient
of vector
control
Slip compensation coefficient is used to
adjust the slip frequency of the vector control
and improve the speed control accuracy of
the system. Adjusting the parameter properly
can control the speed steady-state error.
100%