Extreme Hoops operation manual
1. Out of tickets.
2. Tickets jammed
3. Poor connection on the
ticket dispenser
1. Refill tickets, press reset button
2. Unjam the tickets and then press
the reset button
3. Replace with a better connector
Does not
score when
ball goes in
1. Reflective paper is worn or
old.
2. Poor connection.
3. Ball sensor is damaged.
1. Replace the reflective paper.
2. Make sure the connection is good.
3. Replace with new sensor.
1. Sensors disconnected
2. Rim detect sensor is
damaged.
1. Connect the sensor.
2. Replace the sensor board.
1. Relay is not working.
2. Motor is not working.
3. Faulty connectors.
1. Check the power voltage to see if it
is the same as motor voltage.
2. Check wire is connected properly.
3. Replace with new sensor.
1. Sensor connector is loose.
2. Sensor is not working.
1. Connect the wire properly.
2. Replace with new sensor.
Ball gate
does not
open or close
1. Drive board sensor is not
working.
2. Motor is not working.
3. Poor connection.
1. Check the ball sensor input signal;
2. Make sure power voltage is the
same as motor voltage.
3. Make sure every connector is
connected.