8. Chamber Probe Replacement
1. The temperature probe 1 is fixed on
the back of the chamber. The
temperature probe 2 is set in the front
of the chamber.
2. The oven uses probe 1 for measuring
the temperature on the cooking
process. The probe 2 is used in steam
cooking processes (STEAM.Maxi ™) or
when the probe 1 is damaged.
3. Disconnect the equipment
electrically.
4. In the back of the oven disconnect
the wires of the probe 1 (CMB1) or 2
(CMB2) from the power board.
5. Unscrew the 2 screws fixing probe in
the inner part of the chamber.
6. Remove the probe from the outside
of the chamber and insert a new.
7. Upon reconnection on the power
board, the cable of the probe 1 is
longer than the probe 2.