Register multiple controllers
Up to four controllers can be registered to an interface.
All additional controllers in the system must be
registered to the interface.
NOTE!
At least one thermostat must be registered to
the additional controller before registering to
the interface.
See steps 15 and 16 in the “Register thermostat and/
or system device to a controller” section for more
information.
Unregister one channel or system device
When a channel or system device is inaccurately
registered or if a thermostat registration needs to be
redone, it is possible to remove the current registration
from the controller.
NOTE!
The controller must be unregistered in the
interface as well. Go to menu Main menu >
Preferences > RF Link and unregister.
To unregister a channel:
1. Enter registration mode. Channel 1 LED flashes red/
green, or the first unregistered channel flashes red.
2. If a system device (interface etc) is to be
unregistered, enter system channel registration
mode. The power LED flashes according to the
pattern long blink, short pause, long blink and
channel 1 LED flashes red/green.
3. Use buttons < or > to move the pointer (LED
flashes red) to the selected channel (flashes green if
registered) to unregister.
4. Press the < and > buttons simultaneously until the
LED for the selected channel starts flashing red
(about 5 seconds).
Unregister all channels
When one or more channels (thermostats and system
devices) are inaccurately registered, it is possible to
remove all registrations at the same time.
NOTE!
The controller must be unregistered in the
interface as well. Go to menu Main menu >
Preferences > RF Link and unregister.
To cancel all channel registrations:
1. Enter registration mode. Channel 1 LED flashes red/
green, or the first unregistered channel flashes red.
2. Press the < and > buttons simultaneously until the
LEDs for all channels except one turn off (about
10 seconds). The one remaining flashes red.
Room bypass
To reach the bypass settings, the controller must be
registered to the interface.
1. In the interface, go to the Room bypass menu,
Main menu > System settings > Room bypass.
2. Select a controller.
3. Select up to a maximum of two rooms.
4. Press the Confirm button to save and exit the
menu.
Other functions
See full manual for more information about
Autobalancing of actuators (eliminating the need
of manual balancing,on by default), Heat pump
integration, Cooling, Comfort/ECO settings, Smart
Home Gateway, Room check, and Supply check etc.
QUICK GUIDE
10
UPONOR SMATRIX WAVE · QUICK GUIDE
EN
CZ
DE
DK
EE
ES
FI
FR
HR
HU
IT
LT
LV
NL
NO
PL
PT
RO
RU
SE
SI
SK

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Uponor Smatrix Wave T-166 and is the answer not in the manual?

Uponor Smatrix Wave T-166 Specifications

General IconGeneral
BrandUponor
ModelSmatrix Wave T-166
CategoryThermostat
LanguageEnglish

Related product manuals