MT124-032M 331
7.1.9 Access control
The IPerCom system integrates an access control service, which allows the opening of gates (doors, gates,
barriers, etc.) by recognising proximity keys or entering door codes. Call Modules, Entry Panels 1060/21 and
Key Readers can be used to open the access. Call Modules with 1060/48 and Entry Panels 1060/21 integrate
a Proximity Key reader.
The opening of a door is subject to the recognition of a Proximity Key or an access code by a Call Module, an
Entry Panel 1060/21 or a Key Reader.
For a Proximity Key or access code to be valid and thus able to open a certain access point:
• they must be associated with a user (resident or non-resident);
• they must be associated with the access points to be opened.
This is partially already done automatically by the system through the concept of topology and
competence.
Let us supposed to have a building with a block and two stairs like the one shown below:
Figure 431: System consisting of a block with two stairs
There is a main Call Module on the topological node of Block "01", while there is a Key Reader on the
topological node of Stair "02".