Do you have a question about the Utilitech Pro LLT25 and is the answer not in the manual?
Explains the safety alert symbol and defines hazard levels like DANGER, WARNING, and CAUTION.
Warns about explosion hazards from over-pressurized water and stresses the need for a pressure relief valve.
Emphasizes reading and understanding safety messages before installation and operation.
Stresses following state/local codes and consulting professionals for piping and wiring.
Advises installing the tank close to the pressure switch and setting it correctly to prevent pump damage.
Mandates installing a pressure relief valve and protecting the system from freezing temperatures.
Lists conditions like freezing, chemicals, high pressure, and high temp that can damage the tank.
Warns that improper installation, adjustment, or service can lead to death or serious injury.
Details tank design for cold water, pressure limits, and manufacturer's liability disclaimer.
Provides specific instructions for installing a pressure relief valve and its discharge pipe.
Emphasizes protecting the system from freezing and warns against exceeding operating pressure limits.
Guides on expelling air, priming the pump, and adjusting the tank's precharge pressure.
Presents data on tank capacity and drawdown at different pressure ranges.
Lists the tank's dimensions (A, B, C) and discharge connection size (E).
States the weight of the pump tank.
Discusses acceptable piping materials and the critical need for airtight joints.
Outlines steps for draining the system before servicing or to prevent freezing.
Lists the necessary materials for installing diaphragm tanks.
Details completing pump assembly and placing the tank in the desired location.
Explains threading the tank tee and street tee for connections.
Covers connecting the inlet adapter and the PVC piping to the pump discharge.
Covers installing the pressure relief valve and boiler drain.
Details connecting nipple, tank cross, street tee, relief valve, and boiler drain.
Explains connecting the 1 in. male PVC adapter to the inlet side of the tank cross.
Describes connecting the pressure switch, gauge, and piping to the tank cross.
Specifies setting tank pressure 2 PSI lower than pump cut-on pressure and checking with a gauge.
Discusses using in-line or horizontal tanks where space is critical.
Explains how to install multiple tanks for increased capacity.
Outlines steps for owners to make a warranty claim, including registration and store return.
Defines who is covered, the duration, and conditions for the lifetime limited warranty.
Details what the manufacturer will do if the tank fails, including replacement.
Lists conditions and uses that are not covered by the warranty.
States manufacturer's non-liability for incidental, consequential, or water damage.
Explains how state laws may affect warranty provisions and owner's rights.
Provides crucial notes on preventing water damage from leaks and piping pressure relief valves.
| Brand | Utilitech Pro |
|---|---|
| Model | LLT25 |
| Category | Tank Equipment |
| Language | English |