1
Questions, problems, missing parts? Before returning to your retailer, call our Technical
Assistance Team at 1-800-549-6233, 7:00 a.m.-7:00 p.m., CST, Monday-Friday.
ITEM # 119032
PUMP TANK
MODEL # LLT25
Français p. 13
Español p. 25
PRINTED IN USA 0709 316555-000
Question and Answer IconNeed help?

Do you have a question about the Utilitech Pro LLT25 and is the answer not in the manual?

Summary

SAFE INSTALLATION USE AND SERVICE

Safety Alert Symbol and Hazard Definitions

Explains the safety alert symbol and defines hazard levels like DANGER, WARNING, and CAUTION.

GENERAL SAFETY

Explosion Hazard and Pressure Relief Valve

Warns about explosion hazards from over-pressurized water and stresses the need for a pressure relief valve.

Importance of Manual and Safety Message Understanding

Emphasizes reading and understanding safety messages before installation and operation.

IMPORTANT INSTRUCTIONS BEFORE INSTALLATION

Code Adherence and Professional Consultation

Stresses following state/local codes and consulting professionals for piping and wiring.

Tank Placement and Pressure Switch Setting

Advises installing the tank close to the pressure switch and setting it correctly to prevent pump damage.

Pressure Relief Valve and Freezing Protection

Mandates installing a pressure relief valve and protecting the system from freezing temperatures.

Conditions Causing Damage and Voiding Warranty

Lists conditions like freezing, chemicals, high pressure, and high temp that can damage the tank.

General Installation and Service Risks

Warns that improper installation, adjustment, or service can lead to death or serious injury.

System Design and Safety Precautions

Tank Design, Pressure Limits, and Liability

Details tank design for cold water, pressure limits, and manufacturer's liability disclaimer.

Pressure Relief Valve Installation and Discharge Pipe

Provides specific instructions for installing a pressure relief valve and its discharge pipe.

System Protection and Operating Pressure Limits

Emphasizes protecting the system from freezing and warns against exceeding operating pressure limits.

Air Expulsion, Priming, and Tank Precharge Adjustment

Guides on expelling air, priming the pump, and adjusting the tank's precharge pressure.

TANK SPECIFICATIONS

Capacity and Drawdown Data

Presents data on tank capacity and drawdown at different pressure ranges.

Dimensional and Discharge Connection Data

Lists the tank's dimensions (A, B, C) and discharge connection size (E).

Tank Weight

States the weight of the pump tank.

PIPING GUIDELINES

Material Choice and Airtight Connections

Discusses acceptable piping materials and the critical need for airtight joints.

DRAINING FOR SERVICING OR FOR WINTER

Draining Procedure and Safety

Outlines steps for draining the system before servicing or to prevent freezing.

DIAPHRAGM TANK INSTALLATION

General Materials Required

Lists the necessary materials for installing diaphragm tanks.

TYPICAL JET PUMP INSTALLATION

Step 1: Pump Assembly and Tank Placement

Details completing pump assembly and placing the tank in the desired location.

Step 2: Tank Tee and Street Tee Connections

Explains threading the tank tee and street tee for connections.

Step 3: Inlet Adapter and Piping Connections

Covers connecting the inlet adapter and the PVC piping to the pump discharge.

Step 4: Relief Valve and Boiler Drain Installation

Covers installing the pressure relief valve and boiler drain.

TYPICAL SUBMERSIBLE PUMP INSTALLATION

Step 1: Initial Component Connections

Details connecting nipple, tank cross, street tee, relief valve, and boiler drain.

Step 2: Inlet Adapter to Tank Cross

Explains connecting the 1 in. male PVC adapter to the inlet side of the tank cross.

Step 3: Pressure Switch and Gauge Connections

Describes connecting the pressure switch, gauge, and piping to the tank cross.

Setting the Tank Pressure

Pressure Adjustment Guideline

Specifies setting tank pressure 2 PSI lower than pump cut-on pressure and checking with a gauge.

Other Tank Installations

In-line and Horizontal Tank Options

Discusses using in-line or horizontal tanks where space is critical.

Multiple Tank Configurations

Explains how to install multiple tanks for increased capacity.

WARRANTY

Warranty Claim Procedure

Outlines steps for owners to make a warranty claim, including registration and store return.

Lifetime Limited Warranty Coverage

Defines who is covered, the duration, and conditions for the lifetime limited warranty.

Manufacturers Obligations

Details what the manufacturer will do if the tank fails, including replacement.

Warranty Exclusions

Lists conditions and uses that are not covered by the warranty.

Liability Limitations

States manufacturer's non-liability for incidental, consequential, or water damage.

State Law and Legal Rights

Explains how state laws may affect warranty provisions and owner's rights.

Important Installation Notes

Provides crucial notes on preventing water damage from leaks and piping pressure relief valves.