SCUBAPRO S600-S550 SECOND STAGES
2003 SCUBAPRO
Important note
: The following information is not designed to be a complete training guide for servicing the listed SCUBAPRO regulators. All SCUBAPRO
technicians are required to attend an annual service training program to insure safe handling and servicing of SCUBAPRO products. All SCUBAPRO technicians
must be employed by an authorized SCUBAPRO facility.
6
Remove the cracking effort adjustment
knob from the air barrel.
Remove the decal from the cracking
effort adjustment knob. This will allow
access to the balance and anti-set
mechanisms.
P
/
N
4
3
0
4
0
0
0
0
TOOLS
NEEDED
No tools needed
this step
Remove the plug from the air barrel.
Remove the poppet, balance chamber,
and spring from the air barrel.
Remove all o’rings and poppet seat.
Using the Philips screwdriver remove
the cover screw and o’ring. Do not
remove the breathing effort adjustment
knob at this time.
Remove the poppet, spring and
balance chamber from the air barrel.

Questions and Answers: