26
DISPLAY DATA DESCRIPTION DEFAULT MEMO
DATA DATA
dEF no/Si no
t.AP1 0 ÷ 120 s 22.5
t.AP2 0 ÷ 120 s 22.5
t.APP 0 ÷ t.AP1 6.0
t.Ch1 0 ÷ 120 s 23.5
t.Ch2 0 ÷ 120 s 23.5
t.ChP 0 ÷ t.Ch1 7.0
t.C2P 0 ÷ t.ChP 0.0
r.AP 0 ÷ 120s 1.0
r.Ch 0 ÷ 120s 3.0
t.SEr 0 ÷ 120s 3.0
t.ASE 0 ÷ t.SEr 0.0
t.inv 0 ÷ 120s 0.0
t.PrE 0 ÷ 120s 1.0
t.rAL 0 ÷ 120s 0.0
t.CvE 0 ÷ 120s 0.0
Pot. 30 ÷ 100% 40
SPUn no/Si Si
St.AP PAUS
no
ChiU
PAUS
St.Ch StoP
Stop
APEr
St.PA ChiU
no
ChiU
SP.AP PAUS
no
ChiU
PAUS
Ft.PA r.PAU
r.PAU
t.PCh
Ch.AU no
no
t.PAU
LUCi t.LUC=60s
CiCL
t.LUC
AUS
tiM
biSt
Mon
LP.PA no/Si no
In.LP no/Si no
OroL no/Si no
FUNCTION TABLE PD1
Load V2 ELETTRONICA standard data
Gate 1 opening time
Gate 2 opening time
Opening time of pedestrian gate
Gate 1 closing time
Gate 2 closing time
Closing time of pedestrian gate
Closing time gate 2 during pedestrian cycle
Gate delay during opening
Gate delay during closing
Lock time
Lock advance time
Backlash time
Pre – flashing time
Slowing down time (PD5 only)
Fast closing time after slowing down during closing
Motor power
Start off
Start in opening
- Start command is not available
- Command close gate
- Stop the gate and goes in pause
Start in closing
- Start command stop the gate
- Start command open the gate
Start in pause
- Start command is not available
- Start command closes the gate
Pedestrian in opening
- Pedestrian start command is not available
- Pedestrian start command closes the gate
- Gate goes in pause
Photocell in pause
- Pause time recharged
- Gate stop for a time to be set between 0 to 120 s
Automatic closing
- Automatic closing not available
- Reclosing is available, the standstill time is set from 0 to 999 s
Courtesy Light
- Lights are on trough the whole cycle
- Lights start time adjustable from 0 to 999 s
- Auxiliary output
- Timed aux out (from 0 to 999 s)
- Aux out relay with bistable functioning
- Aux out relay with monostable functioning
Flashlight in pause
Flashlight with intermittence
Timer function