Fault tracing vacon • 47
Local contacts: http://drives.danfoss.com/danfoss-drives/local-contacts/
7
Figure 10. Fault tracing diagram for Modbus TCP
.
Check cabling
Check parameter
M1.15 OR P3.2.1
No communication
Counter OK
Poor
communication
Check communi-
cation status (par.
5.7.3.2.1/5.8.3.2.2)
Counter does not
run
Counter for bad
frames (see Table
3) increases
Check fieldbus
parameters
busparametersin
menu
Check other field-
Check selected
protocol
Is the device in
READY state?
Check Master’s
parameters
Is fieldbus selected
as control place?
Does Master give
RUN command?
Check cabling
Other bus devices
Check connections
Check the led on
keypad
Check external
interlockings (I/O)
Check distances
between cables,
see chapter 4.4.
Check stripping of
cables and
conductors, see
chapter 4.
Use keypad to
monitor variable
Check cable for
cuts
Check correct place-
ment of conductors
in terminals
Check other
necessary devices
(e.g. router)
Drive does not
start from the bus
Check cable types
and lenghts, see
chapter 3.
Check e.g WLAN
or other routers
Check IP address,
gateway etc.
9329.emf