6 • vacon TECHNICAL SPECIFICATIONS
Tel: +358-201-2121 • Fax: +358-201-212 205
2. TECHNICAL SPECIFICATIONS
2.1 Inverter ratings
Range of input voltages 340-800Vcc, 50 Hz, 3~
Inverter
type
Nom. output
power
[kW]
Recommended
max PV power
[kW]
Max al-
lowed PV
power
[A]
Max effi-
ciency [%]
Power con-
sumption at
night
[W]
Inverter
dimensions
[mm]
Inverter
weight
[kg]
NXV0010 10 12 50 >94% <5 600x1481x600 220
NXV0015 15 18.5 50 >94%
<5 600x1481x600 220
NXV0020 20 24 99 >94%
<5 600x1481x600 300
NXV0025 25 30 99 >94%
<5 600x1481x600 300
NXV0030 30 36 99 >94%
<5 600x1481x600 300
NXV0040 40 48 198 >95% <30 800x1881x600 550
NXV0050 50 60 198 >96%
<30 800x1881x600 550
NXV0080 80 96 353 >96%
<30 800x2281x600 850
NXV0100 100 120 353 >96%
<30 800x2281x600 850
Table 2-1. Power ratings, dimensions and weights
2.2 Technical data
Range of input voltages 340...800 VDC
Maximum input voltage 900 VDC
Mains voltage 3*400 ± 10%
Galvanic isolation For each isolator transformer attached
Frequency 50/60 Hz ± 0,5%
Cos
>0.99, for output 20%-100% of Pn
Harmonic distortion < 2.5% for output > 30% of power
Consumption at night < 5W (NXV0010...NXV0030); <30 W (NXV0040...NXV0100)
Maximum efficiency > 94...96%
Ambient temperature -10...+40°C; 1-% derating for each degree up to 50°C required
Alfanumeric display per unit with two lines of 14 characters, leds
indicating functioning, plus fault and function push buttons.
Signalling 3 potential free contacts to indicate faults and alarms
Communications May include one of the following communication buses as an op-
tional feature: Modbus RTU, Ethernet (Modbus/TCP), RS485, GPRS,
string and inverter monitoring
May include a monitoring system with http-access as an optional
feature.
IEC61000-3-3 For the product to meet the technical requirements of IEC 61000-3-
3, the supply should have a system impedance accordingly:
≤ NXV0015: Zsys = 0.105 ohm
≤ NXV0030: Zsys = 0.270 ohm
≤ NXV0050: Zsys = 0.176 ohm
≤ NXV0100: Zsys = 0.136 ohm
Altitude Max. 2,000m
Environmental category Indoor, conditioned
Pollution degree PD2
AC (Mains) OVCIII
DC (Panels) OVCII
Table 2-2. Technical data