12. MALFUNCTION AND SEND FOR REPAIR
If the SDB-3 and Bridge Panel PC stops working completely contact VAF Instruments for instructions.
In the event the SDB-3 and Bridge Panel PC parts has to be sent back for repair, you can send it directly
to:
VAF Instruments B.V.
Vierlinghstraat 24
NL-3316 EL Dordrecht
The Netherlands
13. ENVIRONMENT
The SDB-3 and Bridge Panel PC equipment has no negative influence on the environment during normal
operation.
14. DISPOSAL
The SDB-3 and Bridge Panel PC equipment is made out of metal and electronics. It should be disposed
according to local laws of the country.
15. TROUBLE SHOOTING
If the SDB-3 and Bridge Panel PC does malfunction, power down the SDB-3 and Bridge Panel PC, check
all wiring and power up the SDB-3 and Bridge Panel PC back again. This will restart the program.
If the malfunction remain, check paragraph 7.5.3.
16. CLASSIFICATIONS OF THE SDB-3 AND BRIDGE PANEL PC
The SDB-3 and Bridge Panel PC are tested in accordance with:
Vibration Test according to IEC 60068-2-6
Power Supply Variations Test
Conducted Low Frequency Immunity Test
Electrical Fast Transients/Burst Immunity Test according to IEC 61000-4-4
Electrical Slow transients/surge immunity Test according to IEC 61000-4-5
Conducted Radio Frequency Immunity Test according to IEC 61000-4-6
Radiated Electromagnetic Field Immunity Test according to IEC 61000-4-3
Electrostatic Discharge Immunity Test according to IEC 61000-4-2
Radiated Emission according to CISPR 16-2-3 & IEC 60945
Conducted Emission according to CISPR 16-2-1
Cold Test according to IEC 60068-2-1
Dry Heat Test according to IEC 60068-2-2
Damp Heat Test according to IEC 60068-2-30
In case of excessive water entering the speaker compartment of the Bridge Panel PC, use air to blow
out the speaker compartment. The SDB-3 and Bridge Panel PC are both IP44 tested successfully.