7.5.3 Alarms
At the top of the screen you will find a tab Alarms representing the internal Sensor Alarm functions. In
case the Bridge Panel PC detects an alarm the ShaPoLi and Alarms tab blink red. An Alarm Message
will appear on the Current Alarm screen.
The Alarms menu is divided in 2 submenus:
• Current Alarms
• Alarm log
Current Alarms:
In the situation of an alarm due to an error in the system, an alarm message will pop-up in the Current
Alarms submenu. All active (current) alarms are shown in this overview and can be Silenced and
Accepted by touching the Silence and/or Accept button behind the specific alarm, in order to Silence
and/or accept the internal alarms.
An alarm can be triggered for one of the following reasons:
- Power is above the EEXI Shaft Power Limit
- T-Sense
®
/TT-sense
®
(over MODBUS) communication failure
- NMEA communication failure
- Some of the expected power sensors have not been enabled
- Individual sensor (Torque, Speed, Power) communication failure if using an analogue power
sensor
- Missing encrypted ShaPoLi settings
- IO communication failure