EasyManua.ls Logo

Vahterus Plate - Page 27

Vahterus Plate
31 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
52 53
Problem Cause Checks Action NB
Pressure
dierence
Meas-
ureow
rates and
pressure
dierence
Temperature Compare
these
values to
the PSHE’s
thermo-
technical
data sheet
Liquidow Check pump
operation
Change
pump
Very poor
performance
and low
pressure
dierence
Flow director
damaged
by pressure
shock or
unsuitable
processuid
Check the
information
on the name
plate: are the
temperature,
and liquids
correct?
Check the
process
data if it is
available
Contact the
manufac-
turer
Problem Cause Checks Action NB!
Internal leak
(uidmix)
Plate
cracked due
to water
hammer
or thermal
shock
Check that
plate side
liquid is
visible on
shell side
(leakinguid
will be visible
on the outlet
pipe)
Contact
Vahterus
Hole in
plate due to
corrosion
Close plate
or shell side
valves and
use a metre
to see if the
pressure is
falling
Problem Cause Checks Action NB
External
leakage
between
cover plate
andange
(openable
model)
Leaking
gasket
Look for leak Tighten
bolts. If
retightening
does not
stop the
leak, remove
cover plate
and change
gasket
The Tech-
nical Data
sheet
contains
details of the
gasket. See
tightening
torque in
section 5.3.4