41Instructions for installation and servicing ecoTEC
Tighten the four nuts (4) on the alternate left and
right sides until the burner door fits closely and uni-
formly to the stop surfaces.
Reconnect the HT lead (5) and earth lead (6) to the
spark electrode.
Insert the cables (8) on the fan motor and the cable
(7) on the gas fitting.
2
3
1
Fig. 7.7 Refitting the gas supply
Reconnect the gas supply (3) to the gas valve, ensur-
ing that a new sealing washer is used and correctly
located. Use the spanner flat at the flexible gas line to
hold the gas fittings.
11
Fig. 7.8 Testing the gas supply for soundness
Turn on the gas supply and test for soundness. Check
especially the screwed connections (3) and (11).
Refit the air inlet pipe, ensuring that the blue seal in
the air intake pipe is correctly located.
7.3 Cleaning the condensate siphon
1
Fig. 7.9 Cleaning the condensate siphon
Danger!
Note that if the boiler is run with an empty
condensate trap there is a danger that fumes
might escape into the room and cause poison-
ing. For this reason, it is important to ensure
that the trap is topped up each time the unit is
cleaned.
Remove the lower part (1) of the condensate siphon by
turning the bayonet catch in anticlockwise direction.
Clean the siphon part section by rinsing it out with
water.
Fill the lower part with water until about 10 mm below
the upper edge.
Fasten the lower part again on the condensate siphon.
Inspection and maintenance 7

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Vaillant ecoTEC plus 831 and is the answer not in the manual?

Vaillant ecoTEC plus 831 Specifications

General IconGeneral
ModelecoTEC plus 831
CategoryBoiler
Output31 kW
ERP RatingA
MountingWall-mounted
Boiler TypeCombi
TypeCondensing
FuelNatural Gas
Warranty5 years
Efficiency89.3%
Dimensions720mm x 440mm x 338mm

Related product manuals