What does it mean if my Vaillant Boiler shows eBUS undervoltage?
C
Christopher RossSep 7, 2025
An eBUS undervoltage indication means there could be a short circuit on the eBUS, an overload on the eBUS, or two power sources on the eBUS with different polarity. Check the eBUS connections and power sources.
T
Thomas AndersonAug 25, 2025
What to do if the heating system of my Vaillant ecoTEC plus 824 is not full of water?
G
gregorymooreAug 25, 2025
If your Vaillant Boiler's heating system isn't full of water or charged correctly, make sure the heating system is full of water and charged to between 1 and 1.5 bar. If it's not, refill and vent the system.
T
Taylor CallahanAug 25, 2025
What to do if my Vaillant ecoTEC plus 824 is dry firing?
D
Dr. Tammy McguireAug 26, 2025
If your Vaillant Boiler is dry firing, it indicates there may be too little water in the appliance, a defective water shortage switch, a defective cable to the pump or water shortage switch, a blocked or defective pump, or the pump output is too low. Ensure adequate water supply and check the water shortage switch and pump.
S
Samantha ObrienSep 16, 2025
What to do if my Vaillant ecoTEC plus 824 shows flow and/or return NTC fault?
V
vargasdebbieSep 16, 2025
If there is a flow and/or return NTC fault, the flow and/or return NTC is defective (tolerances too big). Replace the flow and/or return NTC.
C
Connor YoungSep 23, 2025
What to do if the gas supply to my Vaillant ecoTEC plus 824 Boiler is off?
D
Deborah EvansSep 23, 2025
If the gas supply to your Vaillant Boiler is off or not correctly purged, check that the gas supply to the boiler is on, that it has been correctly purged, and that an inlet pressure of 20 mbar is available at the gas valve.
L
lstewartSep 12, 2025
How to fix Return NTC short circuit in Vaillant ecoTEC plus 824 Boiler?
D
Denise MullenSep 12, 2025
A Return NTC short circuit can be caused by a defective NTC, a short circuit in the cable harness, or a cable/casing shortcut. Replace the NTC and inspect the cable harness.
B
boyerjermaineSep 2, 2025
What causes a short circuit in the tank sensor of my Vaillant ecoTEC plus 824?
J
Jacob CollinsSep 2, 2025
A short circuit in the tank sensor of your Vaillant Boiler can be caused by a defective NTC, an earth leak/short circuit in the cable loom, or a damp plug connection. Inspect and replace the NTC or repair damp connections.
P
Patrick StrongSep 3, 2025
What does it mean 'No valid DSN in AI and/or BMU' in Vaillant ecoTEC plus 824?
E
Erin MaddoxSep 3, 2025
If your Vaillant Boiler displays 'No valid DSN in AI and/or BMU', it indicates a spare part failure where the AI and motherboard were interchanged at the same time. Replace faulty components to resolve DSN issue.
G
Gregg WagnerSep 23, 2025
What to do if my Vaillant ecoTEC plus 824 has no communication to mainboard?
D
Dustin GilbertSep 23, 2025
If there is no communication to the mainboard, there might be a connection error between the display and the mainboard. Check the connections to the mainboard.
N
Nicholas WilsonAug 29, 2025
What to do if there is a short circuit in the flow-NTC of my Vaillant ecoTEC plus 824 Boiler?
B
Brian JohnsonAug 29, 2025
If there is a short circuit in the flow-NTC of your Vaillant Boiler, it could be due to the NTC plug shorted to the casing or a defective NTC. Inspect and replace the NTC if defective.