What does it mean if my Vaillant Boiler shows eBUS undervoltage?
C
Christopher RossSep 7, 2025
An eBUS undervoltage indication means there could be a short circuit on the eBUS, an overload on the eBUS, or two power sources on the eBUS with different polarity. Check the eBUS connections and power sources.
T
Thomas AndersonAug 25, 2025
What to do if the heating system of my Vaillant ecoTEC plus 824 is not full of water?
G
gregorymooreAug 25, 2025
If your Vaillant Boiler's heating system isn't full of water or charged correctly, make sure the heating system is full of water and charged to between 1 and 1.5 bar. If it's not, refill and vent the system.
T
Taylor CallahanAug 25, 2025
What to do if my Vaillant ecoTEC plus 824 is dry firing?
D
Dr. Tammy McguireAug 26, 2025
If your Vaillant Boiler is dry firing, it indicates there may be too little water in the appliance, a defective water shortage switch, a defective cable to the pump or water shortage switch, a blocked or defective pump, or the pump output is too low. Ensure adequate water supply and check the water shortage switch and pump.
J
John JonesAug 26, 2025
Why does the flame go off during operation in my Vaillant ecoTEC plus 824 Boiler?
T
Taylor ZunigaAug 26, 2025
If the flame goes off during operation and subsequent ignition attempts fail in your Vaillant Boiler, it could be due to a temporarily stopped gas supply, spark failure in the ignition transformer, or faulty earthing of the appliance. Check gas supply and ignition system for faults.
R
Rita WagnerSep 7, 2025
What to do if my Vaillant ecoTEC plus 824 shows a gas valve shutoff delay?
M
Ms. Mary Knox DVMSep 7, 2025
If your Vaillant Boiler shows a gas valve shutoff delay, the gas valve may be leaking, or the electronics may be defective. Inspect the gas valve for leaks and test the electronics.
D
David SmithSep 10, 2025
How to fix Flow NTC open circuit in Vaillant Boiler?
M
Michael CoxSep 10, 2025
A Flow–NTC open circuit can be caused by a broken NTC, a broken NTC cable, a defective connection at the NTC, or a defective connection at the electronics. Check and repair the NTC and connections.
B
boyerjermaineSep 2, 2025
What causes a short circuit in the tank sensor of my Vaillant ecoTEC plus 824?
J
Jacob CollinsSep 2, 2025
A short circuit in the tank sensor of your Vaillant Boiler can be caused by a defective NTC, an earth leak/short circuit in the cable loom, or a damp plug connection. Inspect and replace the NTC or repair damp connections.
P
Patrick StrongSep 3, 2025
What does it mean 'No valid DSN in AI and/or BMU' in Vaillant ecoTEC plus 824?
E
Erin MaddoxSep 3, 2025
If your Vaillant Boiler displays 'No valid DSN in AI and/or BMU', it indicates a spare part failure where the AI and motherboard were interchanged at the same time. Replace faulty components to resolve DSN issue.
D
Daniel MckeeAug 30, 2025
What to do if the water pressure sensor or cable harness hydraulics are defective in my Vaillant Boiler?
A
andersonrobertAug 30, 2025
If the water pressure sensor or cable harness hydraulics are defective in your Vaillant Boiler, it could be due to a broken line to the water pressure sensor, a short-circuit at 0 V, or a defective water pressure sensor. Inspect and replace the water pressure sensor or repair the line.
N
Nicholas WilsonAug 29, 2025
What to do if there is a short circuit in the flow-NTC of my Vaillant ecoTEC plus 824 Boiler?
B
Brian JohnsonAug 29, 2025
If there is a short circuit in the flow-NTC of your Vaillant Boiler, it could be due to the NTC plug shorted to the casing or a defective NTC. Inspect and replace the NTC if defective.