What to do if the water pressure sensor or cable harness hydraulics are defective in my Vaillant Boiler?
A
andersonrobertAug 30, 2025
If the water pressure sensor or cable harness hydraulics are defective in your Vaillant Boiler, it could be due to a broken line to the water pressure sensor, a short-circuit at 0 V, or a defective water pressure sensor. Inspect and replace the water pressure sensor or repair the line.
M
Michelle WhitneySep 7, 2025
What does it mean if my Vaillant Boiler shows eBUS undervoltage?
C
Christopher RossSep 7, 2025
An eBUS undervoltage indication means there could be a short circuit on the eBUS, an overload on the eBUS, or two power sources on the eBUS with different polarity. Check the eBUS connections and power sources.
N
Nicholas WilsonAug 29, 2025
What to do if there is a short circuit in the flow-NTC of my Vaillant ecoTEC plus 824 Boiler?
B
Brian JohnsonAug 29, 2025
If there is a short circuit in the flow-NTC of your Vaillant Boiler, it could be due to the NTC plug shorted to the casing or a defective NTC. Inspect and replace the NTC if defective.
K
Kevin ClarkSep 18, 2025
What does it mean if my Vaillant Boiler water pressure sensor signal is out of range (too high)?
M
Michael RivasSep 18, 2025
If the water pressure sensor signal is out of range (too high), the cable to the water pressure sensor has a short-circuit at 5 V / 24 V, or there is an internal fault in the water pressure sensor. Inspect and repair the cable and replace the water pressure sensor.
K
Kyle SmithSep 8, 2025
Why is the safety temperature limiter by NTC activated in my Vaillant Boiler?
D
Douglas GonzalezSep 8, 2025
The safety temperature limiter by NTC might be activated because the Flow-NTC is not correctly thermal-connected or is defective, causing the appliance not to shut down. Check the thermal connection of the Flow-NTC and replace it if defective.
L
lstewartSep 12, 2025
How to fix Return NTC short circuit in Vaillant ecoTEC plus 824 Boiler?
D
Denise MullenSep 12, 2025
A Return NTC short circuit can be caused by a defective NTC, a short circuit in the cable harness, or a cable/casing shortcut. Replace the NTC and inspect the cable harness.
S
Samantha ObrienSep 16, 2025
What to do if my Vaillant ecoTEC plus 824 shows flow and/or return NTC fault?
V
vargasdebbieSep 16, 2025
If there is a flow and/or return NTC fault, the flow and/or return NTC is defective (tolerances too big). Replace the flow and/or return NTC.
C
Connor YoungSep 23, 2025
What to do if the gas supply to my Vaillant ecoTEC plus 824 Boiler is off?
D
Deborah EvansSep 23, 2025
If the gas supply to your Vaillant Boiler is off or not correctly purged, check that the gas supply to the boiler is on, that it has been correctly purged, and that an inlet pressure of 20 mbar is available at the gas valve.
J
John JonesAug 26, 2025
Why does the flame go off during operation in my Vaillant ecoTEC plus 824 Boiler?
T
Taylor ZunigaAug 26, 2025
If the flame goes off during operation and subsequent ignition attempts fail in your Vaillant Boiler, it could be due to a temporarily stopped gas supply, spark failure in the ignition transformer, or faulty earthing of the appliance. Check gas supply and ignition system for faults.
T
Taylor CallahanAug 25, 2025
What to do if my Vaillant ecoTEC plus 824 is dry firing?
D
Dr. Tammy McguireAug 26, 2025
If your Vaillant Boiler is dry firing, it indicates there may be too little water in the appliance, a defective water shortage switch, a defective cable to the pump or water shortage switch, a blocked or defective pump, or the pump output is too low. Ensure adequate water supply and check the water shortage switch and pump.