What to do if the water pressure sensor or cable harness hydraulics are defective in my Vaillant Boiler?
A
andersonrobertAug 30, 2025
If the water pressure sensor or cable harness hydraulics are defective in your Vaillant Boiler, it could be due to a broken line to the water pressure sensor, a short-circuit at 0 V, or a defective water pressure sensor. Inspect and replace the water pressure sensor or repair the line.
W
willie61Aug 29, 2025
Why is there a short circuit in the return-NTC of my Vaillant ecoTEC plus 824 Boiler?
A
allenjeffreyAug 29, 2025
A short circuit in the return-NTC of your Vaillant Boiler is often due to a defective NTC. Inspect and replace the NTC if defective.
N
Nicholas WilsonAug 29, 2025
What to do if there is a short circuit in the flow-NTC of my Vaillant ecoTEC plus 824 Boiler?
B
Brian JohnsonAug 29, 2025
If there is a short circuit in the flow-NTC of your Vaillant Boiler, it could be due to the NTC plug shorted to the casing or a defective NTC. Inspect and replace the NTC if defective.
A
alexis40Aug 28, 2025
What causes a broken Return-NTC in a Vaillant ecoTEC plus 824 Boiler?
J
Jessica SteeleAug 28, 2025
A broken Return-NTC in your Vaillant Boiler can be caused by a defective or broken Return-NTC cable, or a faulty NTC. Check and replace NTC or repair cable.
K
Kayla KellyAug 27, 2025
How do I fix a broken Flow-NTC in my Vaillant Boiler?
A
Alexis BartonAug 28, 2025
A broken Flow-NTC in your Vaillant Boiler can be caused by a defective or broken Flow-NTC cable, or a faulty NTC. Check and replace NTC or repair cable.
C
Christine RoseAug 27, 2025
Why is my Vaillant Boiler fan speed too high on start?
J
Janet RileyAug 27, 2025
If your Vaillant Boiler experiences fan speed variation (too high on start), the causes may be:
1. Blocked fans
2. Plug not inserted correctly on the fan
3. Defective hall sensor
4. Fault in cable harness
5. Defective electronics
Inspect fan and connections, and replace defective components.
K
kennethmeyersAug 27, 2025
Why is there a large temperature spread in my Vaillant Boiler?
A
Angela PriceAug 27, 2025
A large temperature spread between the flow and return probe in your Vaillant Boiler, indicating a water shortage, can be caused by a blocked or defective pump, or the pump output being too low. Inspect and repair or replace the pump.
W
Whitney PorterAug 26, 2025
What causes rapid temperature rise in my Vaillant Boiler?
A
Austin StewartAug 27, 2025
A rapid temperature rise in your Vaillant Boiler, indicating a water shortage, can be caused by a blocked pump, insufficient pump output, air in the appliance, low plant pressure, or interchanged flow and return NTCs. Inspect system for air and correct pump issues.
J
John JonesAug 26, 2025
Why does the flame go off during operation in my Vaillant ecoTEC plus 824 Boiler?
T
Taylor ZunigaAug 26, 2025
If the flame goes off during operation and subsequent ignition attempts fail in your Vaillant Boiler, it could be due to a temporarily stopped gas supply, spark failure in the ignition transformer, or faulty earthing of the appliance. Check gas supply and ignition system for faults.
T
Taylor CallahanAug 25, 2025
What to do if my Vaillant ecoTEC plus 824 is dry firing?
D
Dr. Tammy McguireAug 26, 2025
If your Vaillant Boiler is dry firing, it indicates there may be too little water in the appliance, a defective water shortage switch, a defective cable to the pump or water shortage switch, a blocked or defective pump, or the pump output is too low. Ensure adequate water supply and check the water shortage switch and pump.