What to do if my Vaillant ecoTEC plus 824 Boiler shows water shortage and a quick temperature rise?
A
Alexandria OrrSep 6, 2025
If your Vaillant Boiler indicates a water shortage and a quick temperature rise, the pump might be blocked, the pump output might be insufficient, there might be air in the appliance, or the water pressure might be too low. Check and unblock or replace the pump and ensure adequate water pressure.
T
Theresa GuerreroSep 6, 2025
What causes fan speed variation in my Vaillant ecoTEC plus 824?
B
Brian SchmidtSep 6, 2025
Fan speed variation in your Vaillant Boiler can be caused by a blocked fan, a plug not inserted correctly on the fan, a defective hall sensor, a fault in the cable harness, or defective electronics. Check the fan for blockages and connections, and inspect the sensors.
M
Michelle WhitneySep 7, 2025
What does it mean if my Vaillant Boiler shows eBUS undervoltage?
C
Christopher RossSep 7, 2025
An eBUS undervoltage indication means there could be a short circuit on the eBUS, an overload on the eBUS, or two power sources on the eBUS with different polarity. Check the eBUS connections and power sources.