0020288151_04 Operating and installation instructions 9
2.14 Operating and display functions
Note
The functions described in this section are not available for all system configurations.
To call up the menu, press twice.
2.14.1 Menu item CONTROL
MENU
CONTROL
Zone
Heating
Mode:
Manual Uninterrupted retention of the desired temperature
Desired temperature: °C What do the different temperatures mean? (→ Section 2.3)
Time-contr. What is meant by "time period"? (→ Section 2.9)
Weekly planner Up to 12 time periods and desired temperatures can be set per
day.
The competent person sets how the heating installation behaves
outside of the time period in the Set-back mode: function.
In Set-back mode: means:
– Eco: The heating is switched off outside of the time periods.
Frost protection is activated.
– Normal: The set-back temperature applies outside of the time
periods.
The Desired temperature: °C applies within the time periods.
Desired temperature: °C What do the different temperatures mean? (→ Section 2.3)
Set-back temperature: °C What do the different temperatures mean? (→ Section 2.3)
Off Heating is switched off, domestic hot water continues to be avail-
able, frost protection is activated
Cooling
Mode:
Manual Uninterrupted retention of the desired temperature
Desired temperature: °C What do the different temperatures mean? (→ Section 2.3)
Time-contr. What is meant by "time period"? (→ Section 2.9)
Weekly planner Up to twelve time periods can be set per day
The Desired temperature: °C applies within the time periods.
Cooling is switched off outside of the time periods.
Desired temperature: °C What do the different temperatures mean? (→ Section 2.3)
Off Cooling is switched off, domestic hot water remains available.
Name of zone Changing the name Zone 1, which was set at the factory
Absence During this time, heating mode runs at the defined set-back tem-
perature. Domestic hot water mode and circulation are switched
off. Frost protection is activated; existing ventilation runs at the
lowest level.
Factory setting: Set-back temperature: °C 15 °C
All Applies for all zones within the specified time period.
Zone Applies for the selected zone in the specified time period.
Cooling for several days Cooling mode is activated in the specified time period; cooling
mode and desired temperature are used from the Cooling func-
tion
Fixed value control, circuit 1
Mode:
Manual Uninterrupted retention of the Target flow temp., desired: °C that
the competent person set beforehand.
Time-contr. What is meant by "time period"? (→ Section 2.9)