32 Installation instructions VRT 340f
You can select and change the following
parameters:
Display Set by turning the dial
Set-back temperature
Factory setting: 15 °C
Setting range: 5 ... 30° C
Correction of current room
temperature
Adjustment of the displayed
value by up to max.
+/- 3 °C
Factory setting: 0 °C
Display Set by turning the dial
Two-point/analogue
operation
2-point/analogue mode
change-over.
The room temperature
thermostat is set in the
factory as a 2-point
regulation system (set
value 0). You can set it to
analogue mode by changing
the parameter to 1.
11 Start-up