3. Check that the grounding cables have not been pulled too tight.
Keep the curve of the down conductor smooth with a minimum radius of the bent
cable 20 cm (8 in) and never over 90° angles.
CAUTION!
Checking Sensor Cabling and Grounding
If you need to shorten sensor cables, you need:
Cable cutters
Cable stripper
Crimping tool
Pipette (rubber flange only)
Ferrules
Shrinkable tubes or electrical tape
Make sure that you prepare or connect only de-energized wires.WARNING!
To avoid strain on the connector, make sure you connect the cable properly. Too much
strain may cause the cable to fall
o, damage the cable or connector, or make the cable or connector
susceptible to water leakage.
CAUTION!
Do not damage or change the wiring. Incorrect wiring can cause damage and prevent or
limit operation.
CAUTION!
Technical Note M212202EN-A
8 (11)