Troubleshooting
l@
L
l@
,w
w
@
w
I When
you
face
problems
on
your
heater,
please
refer to this check-
table before consulting
your
service
shop.
In case satisfactory
results do not come out
through referring to the
table, or
you
have
problems
not de-
scribed in this table,
please
contact
your
dealer. While consulting
him,
please
describe
the
problem
you
have, together with
type and serial number of
your
heater.
(For
finding the heater's serial
number,
please
refer to
page
16.)
lf the following
phenomenon
takes
place,
it is not
an
irregular trouble.
Please check again
before consulting
your
service shop.
Phenomenon
Possible
Cause
Remedy
The heater does not start.
(The
lamp
does
not light
on.)
Power cord
is
not connected
with an
AC
outlet.
Power supply is cut off.
Please
connect
the
power
cord
with an AC outlet, and
check the
power
supply.
Blown
fuse
Replace fuse with a
new
one.
(Please
refer to
page
14.)
The heater does
not
start.
(The
lamp is lit.)
Safety devices are
working.
Please confirm if
"Flame
Monitoi'
is exposed to any type of
light
(sunlight
or electric lamp, etc.), and
remove the heater
to
pre-
vent the radiation disk from detecting
any type of light directly.
The heater does not ignite.
No fuel in the
fuel tank.
Please
oour
fuel into the
tank.
There is water
in
the
fuel tank.
Please
clean
up the tank and
fill it with fresh/clean fuel.
Fuel filter element is clogged.
Check well the
filter
element
and reolace
it with
a
new one.
Nozzle is clogged
Replace nozzle with a
new
one.
(Please
refer to
page
14.)
The flame
goes
out during
the
operation.
Wrono or
foul fuel is used.
Please clean uo the
fuel tank and fill it with fresh/new
fuel.
Flame
monitor is
dirty.
Please clean up the Flame
Monitor
(Please
refer to
page
12).
Fuel filter element is clogged.
Please check
the filter element and
replace it with a
new one.
Phenomenon
Explanation
When used for the first time, smoke
or smell
comes
out of the heater.
Because fuel is burning
together with dusts, etc.
This
phenomenon
will disap-
oear after
a short while.
At
the
time
of
ignition or shut-down of
the
heater. noise comes from the burner section.
Noise
is
caused
by expansion or shrinkage
of the burner section due
to
temperature's up and down.
This is not irregular.
Exchange
procedure
w
w
w
w
.
Never
service the heater while
it is burning, in operation,
hot or
plugged-in
to avoid
any
injury and/or trouble.
Before starting any service,
to avoid electric shock,
please
make sure
the heater is shut
down and that the
power
cord is disconnected.
When servicing the
heater,
please
wear
gloves