16
7. APPLIANCE PREPARATION
7.1. Window Removal
See figure 12.
• Turn the top three spring loaded window bolts through 90
0
to release the window
from the firebox.
• Remove the bottom three spring-loaded window bolts.
• Detach the chain from the top right corner of the window.
• Carefully lift the window away. Keep the window and bolts in a safe place.
7.2. Ignition Spark Check
The pilot burner and electrode unit is at the left end of the burner.
Push in the lighting knob and turn counter-clockwise through the “IGN” position to
“PILOT”. A spark should flash across from the pilot electrode to the pilot burner shield.
See figure 13.
Figure 13 Ignition spark check
Figure 12 Window removal