Page #24 background imageLoading...
Page #24 background image
24
Appendix A-Remote Control Operation
Setting ºC/24-hr or ºF/12-hr
clock
In MAN mode, press + buttons
until temperature / clock display
changes from
°F / 12-hour °C / 24-hour
Setting Time
The time display will ȵ ash after either:
- installing the battery, or
- pressing +
To set the time, press buttons:
= hour
= minutes
Press or wait to go back to MAN.
Modes of Operation
Brieȵ y press SET cycles through modes
of operation.
MAN
>
TEMP
> > >
TEMP
>
TIMER
>
MAN
NOTE: Press or to reach
MAN
mode.
MAN
Manual Mode
Manual ȵ ame height adjustment.
TEMP
Daytime Temperature Mode
When pilot is lit, room temperature
is measured and compared to set
temperature. Flame height automatically
adjust to reach Daytime Set
Temperature.
Light/Dimmer Mode
Not available on this ȴ replace.
Fan Mode
Turns fan ON and OFF and adjusts speed.
Note: To turn fan OFF, press until all 4 bars
disappear.
TEMP
Night time Setback
Temperature Mode
When pilot is lit, room temperature
is measured and compared to set
temperature. Flame height automatically
adjust to reach Night Time Setback
Temperature.
TIMER
Timer Mode
When pilot is lit, two periods of time
(P1 and P2) can be programmed to use
Daytime and Night time temperatures
at speciȴ c times.
Note: Display shows set temperature
every 30 seconds.
Set the di΍ erent parameters when
they are ȵ ashing.