Adjusting AIR SUPPLY CONTROL
1) Select speed “MIN” or “MAX” using slide switch (A).
When “MIN” (minimum speed) is selected, if the knob
(B) is set above the click, the unit will exchange in low
speed with the outdoors and if it is set below the click,
the unit will exchange on high speed with the outdoors
until the desired humidity level has been reached.
When “MAX” (maximum speed) is selected, the unit will
exchange on high speed with the outdoors no matter if
the knob is set below or above the click.
2) To turn off the unit, slide the switch at the “OFF” position.
2.5 Simple-Touch Bronze Main Control
Activate the push-button. The color of the indicator shows the unit operating mode.
RECIRCULATION
MAX
MIN
VC0146
S-T
COLOR MODE SUGGESTED USE
GREEN RECIRCULATION SELECT THIS MODE WHEN YOU DEEM THE INDOOR
AIR IS TOO DRY IN HEATING SEASON, OR TOO HUMID
DURING COOLING SEASON. IN THIS MODE, THE UNIT
STOPS EXCHANGING WITH THE OUTDOORS AND
RECIRCULATES INDOOR AIR AT HIGH SPEED.
YELLOW MIN. SPEED VENTILATION FOR NORMAL DAILY OPERATION.
RED MAX. SPEED VENTILATION FOR EXCESS POLLUTANTS AND HUMIDITY (PARTIES,
ODORS, SMOKE, ETC.).
2.6 Bronze Main Control
Adjusting DEHUMIDISTAT
Setting during summer months:
During this period, unless being afflicted with breathing problems, using the dehumidistat is
unnecessary. Set the slide switch to “OFF”. (Do not exchange in day time; exchange at night time, if
cool outdoors, or if it is not raining.)
Setting during fall, winter and spring months:
(When severe condensation appears on windows.)
1) Determine the humidity level in your house (bring the knob (B) counterclockwise to its maximum
position, then bring it back clockwise slowly until you hear a “click”).
2) Set the knob to one line under this temperature level or “click”.
It is possible (and normal) to experience condensation on your windows when drastic
changes in temperature happen (for example: -5°C [23°F] to -20°C [-4°F]). In that case, we
suggest waiting a few days to allow the situation to stabilize.
CAUTION
Do not select a temperature below -20°C (-4°F). This could lead to excessive
dryness in the air causing discomfort for the occupants.
After a power failure, the Simple-Touch Bronze wall control will turn off.
2. Controls (contd)
C
O
M
F
O
R
T
Z
O
N
E
O
F
F
%
R
E
L
A
T
I
V
E
H
U
M
I
DIT
Y
70%
60%
50%
40%
30%
25%
20%
HUMIDITY
CONTROL
DURING FALL, WINTER
AND SPRING, SET THE
DIAL ACCORDING TO
THE DESIRED MAXIMUM
INDOOR HUMIDITY LEVEL.
DURING SUMMER SET
THE DIAL TO THE
OFF POSITION.
VC0039